TY - JOUR
T1 - Wise-pattern breast reconstruction
T2 - Modification using alloderm and a vascularized dermal-subcutaneous pedicle
AU - Derderian, Christopher A.
AU - Karp, Nolan S.
AU - Choi, Mihye
PY - 2009/5/1
Y1 - 2009/5/1
N2 - Immediate implant-based breast mound reconstruction offers many advantages over staged implant reconstruction techniques. For large volume breast reconstruction, a Wise-pattern skin resection may provide very good aesthetic results; however, the submuscular implant pocket is inadequate to cover the inferior pole of the breast. In this patient population, the risk of implant exposure from T-point breakdown is significant. We present our technique of Wise-pattern breast reconstruction using AlloDerm (LifeCell, Branchburg, NJ) and a vascularized dermal-subcutaneous pedicle (DSP) to augment the volume and quality of immediate breast implant coverage, particularly in the area of the T-point suture lines.We reviewed a series of 20 consecutive patients with large breasts who were treated with an immediate implant reconstruction of greater than 400 mL volume using the Wise-pattern with DSP. Preoperative and postoperative 3-dimensional surface scan studies were performed to evaluate breast symmetry.The average volume of breast reconstruction in this study group was 458 mL. T-point breakdown occurred in 5 patients (25%). These patients were treated with local wound care and healed with an excellent aesthetic result. None of these patients required implant removal, implant exchange, or operative debridement. Pre- and postoperative 3-dimensional surface scan analysis of these patients demonstrated comparable differences between the affected and unaffected sides in women undergoing immediate breast implant reconstruction when compared with a matched group of patients undergoing 2-stage breast reconstruction with tissue expanders.Wise-pattern skin-reducing mastectomy is an excellent strategy to provide an aesthetically pleasing, immediate implant breast reconstruction. This technique provides breast symmetry that is at least comparable to that of tissue expander-based, staged implant reconstructions. The reliability of the Wise-pattern technique is significantly improved with the addition of AlloDerm to the muscular pocket and a vascularized DSP to preserve the integrity of the reconstruction in the presence of T-point breakdown.
AB - Immediate implant-based breast mound reconstruction offers many advantages over staged implant reconstruction techniques. For large volume breast reconstruction, a Wise-pattern skin resection may provide very good aesthetic results; however, the submuscular implant pocket is inadequate to cover the inferior pole of the breast. In this patient population, the risk of implant exposure from T-point breakdown is significant. We present our technique of Wise-pattern breast reconstruction using AlloDerm (LifeCell, Branchburg, NJ) and a vascularized dermal-subcutaneous pedicle (DSP) to augment the volume and quality of immediate breast implant coverage, particularly in the area of the T-point suture lines.We reviewed a series of 20 consecutive patients with large breasts who were treated with an immediate implant reconstruction of greater than 400 mL volume using the Wise-pattern with DSP. Preoperative and postoperative 3-dimensional surface scan studies were performed to evaluate breast symmetry.The average volume of breast reconstruction in this study group was 458 mL. T-point breakdown occurred in 5 patients (25%). These patients were treated with local wound care and healed with an excellent aesthetic result. None of these patients required implant removal, implant exchange, or operative debridement. Pre- and postoperative 3-dimensional surface scan analysis of these patients demonstrated comparable differences between the affected and unaffected sides in women undergoing immediate breast implant reconstruction when compared with a matched group of patients undergoing 2-stage breast reconstruction with tissue expanders.Wise-pattern skin-reducing mastectomy is an excellent strategy to provide an aesthetically pleasing, immediate implant breast reconstruction. This technique provides breast symmetry that is at least comparable to that of tissue expander-based, staged implant reconstructions. The reliability of the Wise-pattern technique is significantly improved with the addition of AlloDerm to the muscular pocket and a vascularized DSP to preserve the integrity of the reconstruction in the presence of T-point breakdown.
KW - Acellular dermal matrix
KW - Breast reconstruction
KW - Immediate implant reconstruction
UR - http://www.scopus.com/inward/record.url?scp=67449149879&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=67449149879&partnerID=8YFLogxK
U2 - 10.1097/SAP.0b013e3181a0cfee
DO - 10.1097/SAP.0b013e3181a0cfee
M3 - Article
C2 - 19387155
AN - SCOPUS:67449149879
SN - 0148-7043
VL - 62
SP - 528
EP - 532
JO - Annals of Plastic Surgery
JF - Annals of Plastic Surgery
IS - 5
ER -