TY - JOUR
T1 - Variation in Use of High-Flow Nasal Cannula and Noninvasive Ventilation Among Patients With COVID-19
AU - Garcia, Michael A.
AU - Johnson, Shelsey W.
AU - Sisson, Emily K.
AU - Sheldrick, Christopher R.
AU - Kumar, Vishakha K.
AU - Boman, Karen
AU - Bolesta, Scott
AU - Bansal, Vikas
AU - Bogojevic, Marija
AU - Domecq, J. P.
AU - Lal, Amos
AU - Heavner, Smith
AU - Cheruku, Sreekanth R.
AU - Lee, Donna
AU - Anderson, Harry L.
AU - Denson, Joshua L.
AU - Gajic, Ognjen
AU - Kashyap, Rahul
AU - Walkey, Allan J.
N1 - Publisher Copyright:
© 2022 Daedalus Enterprises.
PY - 2022/8
Y1 - 2022/8
N2 - BACKGROUND: The use of high-flow nasal cannula (HFNC) and noninvasive ventilation (NIV) for hypoxemic respiratory failure secondary to COVID-19 are recommended by critical-care guidelines; however, apprehension about viral particle aerosolization and patient self-inflicted lung injury may have limited use. We aimed to describe hospital variation in the use and clinical outcomes of HFNC and NIV for the management of COVID-19. METHODS: This was a retrospective observational study of adults hospitalized with COVID-19 who received supplemental oxygen between February 15, 2020, and April 12, 2021, across 102 international and United States hospitals by using the COVID-19 Registry. Associations of HFNC and NIV use with clinical outcomes were evaluated by using multivariable adjusted hierarchical random-effects logistic regression models. Hospital variation was characterized by using intraclass correlation and the median odds ratio. RESULTS: Among 13,454 adults with COVID-19 who received supplemental oxygen, 8,143 (60%) received nasal cannula/face mask only, 2,859 (21%) received HFNC, 878 (7%) received NIV, 1,574 (12%) received both HFNC and NIV, with 3,640 subjects (27%) progressing to invasive ventilation. The hospital of admission contributed to 24% of the risk-adjusted variation in HFNC and 30% of the risk-adjusted variation in NIV. The median odds ratio for hospital variation of HFNC was 2.6 (95% CI 1.4–4.9) and of NIV was 3.1 (95% CI 1.2-8.1). Among 5,311 subjects who received HFNC and/or NIV, 2,772 (52%) did not receive invasive ventilation and survived to hospital discharge. Hospital-level use of HFNC or NIV were not associated with the rates of invasive ventilation or mortality. CONCLUSIONS: Hospital variation in the use of HFNC and NIV for acute respiratory failure secondary to COVID-19 was great but was not associated with intubation or mortality. The wide variation and relatively low use of HFNC/NIV observed within our study signaled that implementation of increased HFNC/ NIV use in patients with COVID-19 will require changes to current care delivery practices. (ClinicalTrials.gov registration NCT04323787.).
AB - BACKGROUND: The use of high-flow nasal cannula (HFNC) and noninvasive ventilation (NIV) for hypoxemic respiratory failure secondary to COVID-19 are recommended by critical-care guidelines; however, apprehension about viral particle aerosolization and patient self-inflicted lung injury may have limited use. We aimed to describe hospital variation in the use and clinical outcomes of HFNC and NIV for the management of COVID-19. METHODS: This was a retrospective observational study of adults hospitalized with COVID-19 who received supplemental oxygen between February 15, 2020, and April 12, 2021, across 102 international and United States hospitals by using the COVID-19 Registry. Associations of HFNC and NIV use with clinical outcomes were evaluated by using multivariable adjusted hierarchical random-effects logistic regression models. Hospital variation was characterized by using intraclass correlation and the median odds ratio. RESULTS: Among 13,454 adults with COVID-19 who received supplemental oxygen, 8,143 (60%) received nasal cannula/face mask only, 2,859 (21%) received HFNC, 878 (7%) received NIV, 1,574 (12%) received both HFNC and NIV, with 3,640 subjects (27%) progressing to invasive ventilation. The hospital of admission contributed to 24% of the risk-adjusted variation in HFNC and 30% of the risk-adjusted variation in NIV. The median odds ratio for hospital variation of HFNC was 2.6 (95% CI 1.4–4.9) and of NIV was 3.1 (95% CI 1.2-8.1). Among 5,311 subjects who received HFNC and/or NIV, 2,772 (52%) did not receive invasive ventilation and survived to hospital discharge. Hospital-level use of HFNC or NIV were not associated with the rates of invasive ventilation or mortality. CONCLUSIONS: Hospital variation in the use of HFNC and NIV for acute respiratory failure secondary to COVID-19 was great but was not associated with intubation or mortality. The wide variation and relatively low use of HFNC/NIV observed within our study signaled that implementation of increased HFNC/ NIV use in patients with COVID-19 will require changes to current care delivery practices. (ClinicalTrials.gov registration NCT04323787.).
KW - COVID-19
KW - SARS-CoV-2
KW - high-flow nasal cannula
KW - nonin-vasive ventilation
KW - viruses
UR - http://www.scopus.com/inward/record.url?scp=85134809235&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85134809235&partnerID=8YFLogxK
U2 - 10.4187/respcare.09672
DO - 10.4187/respcare.09672
M3 - Article
C2 - 35672139
AN - SCOPUS:85134809235
SN - 0020-1324
VL - 67
SP - 929
EP - 938
JO - Respiratory Care
JF - Respiratory Care
IS - 8
ER -