TY - JOUR
T1 - Toward long-term and accurate augmented-reality for monocular endoscopic videos
AU - Puerto-Souza, Gustavo A.
AU - Cadeddu, Jeffrey A
AU - Mariottini, Gian Luca
N1 - Publisher Copyright:
© 1964-2012 IEEE.
PY - 2014/10/1
Y1 - 2014/10/1
N2 - By overlaying preoperative radiological 3-D models onto the intraoperative laparoscopic video, augmented-reality (AR) displays promise to increase surgeons' visual awareness of high-risk surgical targets (e.g., the location of a tumor). Existing AR surgical systems lack in robustness and accuracy because of the many challenges in endoscopic imagery, such as frequent changes in illumination, rapid camera motions, prolonged organ occlusions, and tissue deformations. The frequent occurrence of these events can cause the loss of image (anchor) points, and thus, the loss of the AR display after a few frames. In this paper, we present the design of a new AR system that represents a first step toward long term and accurate augmented surgical display for monocular (calibrated and uncalibrated) endoscopic videos. Our system uses correspondence-search methods, and a new weighted sliding-window registration approach, to automatically and accurately recover the overlay by predicting the image locations of a high number of anchor points that were lost after a sudden image change. The effectiveness of the proposed system in maintaining a long term (over 2 min) and accurate (less than 1 mm) augmentation has been documented over a set of real partial-nephrectomy laparascopic videos.
AB - By overlaying preoperative radiological 3-D models onto the intraoperative laparoscopic video, augmented-reality (AR) displays promise to increase surgeons' visual awareness of high-risk surgical targets (e.g., the location of a tumor). Existing AR surgical systems lack in robustness and accuracy because of the many challenges in endoscopic imagery, such as frequent changes in illumination, rapid camera motions, prolonged organ occlusions, and tissue deformations. The frequent occurrence of these events can cause the loss of image (anchor) points, and thus, the loss of the AR display after a few frames. In this paper, we present the design of a new AR system that represents a first step toward long term and accurate augmented surgical display for monocular (calibrated and uncalibrated) endoscopic videos. Our system uses correspondence-search methods, and a new weighted sliding-window registration approach, to automatically and accurately recover the overlay by predicting the image locations of a high number of anchor points that were lost after a sudden image change. The effectiveness of the proposed system in maintaining a long term (over 2 min) and accurate (less than 1 mm) augmentation has been documented over a set of real partial-nephrectomy laparascopic videos.
KW - Augmented reality (AR)
KW - endoscopic vision
KW - feature tracking
UR - http://www.scopus.com/inward/record.url?scp=84907452204&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84907452204&partnerID=8YFLogxK
U2 - 10.1109/TBME.2014.2323999
DO - 10.1109/TBME.2014.2323999
M3 - Article
C2 - 24835126
AN - SCOPUS:84907452204
SN - 0018-9294
VL - 61
SP - 2609
EP - 2620
JO - IRE transactions on medical electronics
JF - IRE transactions on medical electronics
IS - 10
M1 - 2323999