T1 - The Perils of Buddy Wire Use With a Filterwire
AU - Gutierrez, Alessandra
AU - Chugh, Yashasvi
AU - Kostantinis, Spyridon
AU - Brilakis, Emmanouil S.
N1 - Publisher Copyright:
© 2022 Elsevier Inc.
PY - 2022/7
Y1 - 2022/7
N2 - Embolic protection devices may decrease the risk of distal embolization during percutaneous coronary intervention of saphenous vein graft and highly thrombotic lesions. Use of a buddy wire can facilitate equipment delivery but carries perils when used together with a filter. We present two cases demonstrating potential complications of buddy wire use with a filter. In the first case a saphenous vein graft perforation occurred after stenting. A buddy wire and second balloon were used to maintain hemostasis while removing the Filterwire. The buddy wire, however, was caught in the filter retrieval catheter, interlocking the two guide catheters and was eventually removed after forceful pulling. In the second case a Filterwire was used to prevent distal embolization of a highly thrombotic right coronary artery lesion. A buddy wire was used to assist with equipment delivery. A stent was inadvertedly deployed over the buddy wire, entrapping the Filterwire. The entrapped Filterwire was eventually removed after multiple balloon inflations over the buddy wire.
AB - Embolic protection devices may decrease the risk of distal embolization during percutaneous coronary intervention of saphenous vein graft and highly thrombotic lesions. Use of a buddy wire can facilitate equipment delivery but carries perils when used together with a filter. We present two cases demonstrating potential complications of buddy wire use with a filter. In the first case a saphenous vein graft perforation occurred after stenting. A buddy wire and second balloon were used to maintain hemostasis while removing the Filterwire. The buddy wire, however, was caught in the filter retrieval catheter, interlocking the two guide catheters and was eventually removed after forceful pulling. In the second case a Filterwire was used to prevent distal embolization of a highly thrombotic right coronary artery lesion. A buddy wire was used to assist with equipment delivery. A stent was inadvertedly deployed over the buddy wire, entrapping the Filterwire. The entrapped Filterwire was eventually removed after multiple balloon inflations over the buddy wire.
UR - http://www.scopus.com/inward/record.url?scp=85123743813&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85123743813&partnerID=8YFLogxK
U2 - 10.1016/j.carrev.2022.01.001
DO - 10.1016/j.carrev.2022.01.001
M3 - Article
C2 - 35086774
AN - SCOPUS:85123743813
SN - 1553-8389
VL - 40
SP - 214
EP - 217
JO - Cardiovascular Revascularization Medicine
JF - Cardiovascular Revascularization Medicine
ER -