TY - JOUR
T1 - SU‐GG‐T‐69
T2 - Comparison of Three Optimization Methods of BrachyVision™ for IORT Using HDR and HAM Applicator
AU - Zhuang, T.
AU - Steffey, B.
AU - Song, H.
AU - Craciunescu, O.
PY - 2010/6
Y1 - 2010/6
N2 - Purpose: To compare the three optimization methods in BrachyVision™ (Varian Medical Systems, Palo Alto, CA) for flat surface implants using the HAM applicator; To study the effect of curvature of a surface implant on dosimetry. Method and Materials: Flat surface implants were generated in BrachyVision™ using three different optimization strategies offered in BrachyVision™: geometrical optimization normalized to a reference point (GO), volume optimization using reference lines (VO_RL), and volume optimization using a PTV concept (VO_PTV). For each plan, the following indices were computed: the coverage index V(x) (percentage of target volume receiving x% of the prescription dose or more) and the homogeneity index HI(x) (=V(100)‐V(x), with x = 140). Two curved geometries, 9 and 20 cm radius, were considered. For each radius, 9 and 18 channels were planned first as if for a flat implant. The obtained dwell times were then directly transferred to corresponding channels in the curved geometry and dose distribution calculated. Another plan was generated using VO_PTV method based on the curved PTV. Plans were compared in terms of V(100) and HI(140) and DVHs for PTV and normal tissue. Results: 1. For flat implants, GO achieves worse coverage index (86.5 %) than the two VO techniques (95.3% and 95.5%). PTV DVHs are comparable between the two VO techniques. While the VO methods use similar optimization time, VO_RL is easier and quicker to setup thus is the fastest method to use. For both 9 and 18 channel HAM and both radii, the difference between the V(100) and HI(140) is minimal between plans generated with flat dwell times and curved dwell times. Conclusion: The VO_RL is the fastest method for planning a flat IORT HAM surface implant. For radius larger than 9 cm, a curved implant can be simplified as a flat implant with negligible dosimetric difference.
AB - Purpose: To compare the three optimization methods in BrachyVision™ (Varian Medical Systems, Palo Alto, CA) for flat surface implants using the HAM applicator; To study the effect of curvature of a surface implant on dosimetry. Method and Materials: Flat surface implants were generated in BrachyVision™ using three different optimization strategies offered in BrachyVision™: geometrical optimization normalized to a reference point (GO), volume optimization using reference lines (VO_RL), and volume optimization using a PTV concept (VO_PTV). For each plan, the following indices were computed: the coverage index V(x) (percentage of target volume receiving x% of the prescription dose or more) and the homogeneity index HI(x) (=V(100)‐V(x), with x = 140). Two curved geometries, 9 and 20 cm radius, were considered. For each radius, 9 and 18 channels were planned first as if for a flat implant. The obtained dwell times were then directly transferred to corresponding channels in the curved geometry and dose distribution calculated. Another plan was generated using VO_PTV method based on the curved PTV. Plans were compared in terms of V(100) and HI(140) and DVHs for PTV and normal tissue. Results: 1. For flat implants, GO achieves worse coverage index (86.5 %) than the two VO techniques (95.3% and 95.5%). PTV DVHs are comparable between the two VO techniques. While the VO methods use similar optimization time, VO_RL is easier and quicker to setup thus is the fastest method to use. For both 9 and 18 channel HAM and both radii, the difference between the V(100) and HI(140) is minimal between plans generated with flat dwell times and curved dwell times. Conclusion: The VO_RL is the fastest method for planning a flat IORT HAM surface implant. For radius larger than 9 cm, a curved implant can be simplified as a flat implant with negligible dosimetric difference.
UR - http://www.scopus.com/inward/record.url?scp=85024809870&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85024809870&partnerID=8YFLogxK
U2 - 10.1118/1.3468455
DO - 10.1118/1.3468455
M3 - Article
AN - SCOPUS:85024809870
SN - 0094-2405
VL - 37
SP - 3200
JO - Medical Physics
JF - Medical Physics
IS - 6
ER -