T1 - Simultaneous Dual-Contrast Imaging of Small Bowel with Iodine and Bismuth Using Photon-Counting-Detector Computed Tomography
T2 - A Feasibility Animal Study
AU - Ren, Liqiang
AU - Rajendran, Kishore
AU - Fletcher, Joel G.
AU - McCollough, Cynthia H.
AU - Yu, Lifeng
N1 - Funding Information:
Received for publication February 9, 2020; and accepted for publication, after revi-sion, April 2, 2020. From the Department of Radiology, Mayo Clinic, Rochester, MN. Conflicts of interest and sources of funding: The research reported in this publication was supported by the National Institutes of Health under award numbers R21 EB024071, R01 EB016966, and C06 RR018898. The content is solely the respon-sibility of the authors and does not necessarily represent the official views of the National Institutes of Health. The device described is a research scanner and not commercially available. Dr McCollough and Dr Fletcher receive industry grant support from Siemens. No other potential conflicts of interest were declared. Correspondence to: Lifeng Yu, PhD, Department of Radiology, Mayo Clinic 200 1st Street SW, Rochester, MN 55905. E-mail: Yu.Lifeng@mayo.edu. Copyright © 2020 Wolters Kluwer Health, Inc. All rights reserved. ISSN: 0020-9996/20/5510–0688 DOI: 10.1097/RLI.0000000000000687
Publisher Copyright:
© Wolters Kluwer Health, Inc. All rights reserved.
PY - 2020/10/1
Y1 - 2020/10/1
N2 - Objectives Dual-energy and multienergy computed tomography (DECT/MECT) has the potential to simultaneously visualize two contrast agents in the small bowel: arterial enhancement of iodine in the bowel wall and enteric enhancement of bismuth in the bowel lumen. The purpose of this study was to explore its feasibility in a swine study using a research whole-body photon-counting-detector (PCD) computed tomography (CT) system. Materials and Methods A phantom study was initially performed to evaluate the quantification accuracy of iodine and bismuth separation from a single PCD-CT scan, which also served as the calibration reference for material decomposition of in vivo swine PCD-CT data. In the animal study, a test bolus scan was first performed to determine the time-attenuation curve for the arterial enhancement, based on which the timing of the PCD-CT dual-contrast scan was determined. A 600 mL homogeneous bismuth-saline solution (180 mL Pepto-Bismol + 420 mL normal saline) was orally administered to the pig using esophageal intubation. Approximately 1 hour after bismuth administration, 40 mL iodine contrast (Omnipaque 350, 5 mL/s) was injected intravenously. A PCD-CT scan was performed 13 seconds after the initiation of the contrast injection to simultaneously capture the arterial enhancement of iodine and the enteric enhancement of bismuth. To provide optimal material separation and quantification, all PCD-CT scans in both phantom and animal studies were operated at 140 kV with 4 energy thresholds of 25, 50, 75, and 90 keV. Results Using a generic image-based material decomposition method, the iodine and bismuth samples were successfully delineated and quantified in the phantom images with a root-mean-square-error of 1.32 mg/mL in iodine measurement and 0.64 mg/mL in bismuth measurement. In the pig study, the enhancing bowel wall containing iodine and the small bowel loop containing bismuth were not differentiable in the original PCD-CT images. However, they were clearly distinctive from each other in the iodine- and bismuth-specific images after material decomposition, as reviewed by an abdominal radiologist. In addition, quantitative analysis showed that the misclassification between the two contrast materials was less than 1.0 mg/mL. Conclusions Our study demonstrated the feasibility of simultaneous imaging of iodine and bismuth in small bowel of swine using PCD-CT.
AB - Objectives Dual-energy and multienergy computed tomography (DECT/MECT) has the potential to simultaneously visualize two contrast agents in the small bowel: arterial enhancement of iodine in the bowel wall and enteric enhancement of bismuth in the bowel lumen. The purpose of this study was to explore its feasibility in a swine study using a research whole-body photon-counting-detector (PCD) computed tomography (CT) system. Materials and Methods A phantom study was initially performed to evaluate the quantification accuracy of iodine and bismuth separation from a single PCD-CT scan, which also served as the calibration reference for material decomposition of in vivo swine PCD-CT data. In the animal study, a test bolus scan was first performed to determine the time-attenuation curve for the arterial enhancement, based on which the timing of the PCD-CT dual-contrast scan was determined. A 600 mL homogeneous bismuth-saline solution (180 mL Pepto-Bismol + 420 mL normal saline) was orally administered to the pig using esophageal intubation. Approximately 1 hour after bismuth administration, 40 mL iodine contrast (Omnipaque 350, 5 mL/s) was injected intravenously. A PCD-CT scan was performed 13 seconds after the initiation of the contrast injection to simultaneously capture the arterial enhancement of iodine and the enteric enhancement of bismuth. To provide optimal material separation and quantification, all PCD-CT scans in both phantom and animal studies were operated at 140 kV with 4 energy thresholds of 25, 50, 75, and 90 keV. Results Using a generic image-based material decomposition method, the iodine and bismuth samples were successfully delineated and quantified in the phantom images with a root-mean-square-error of 1.32 mg/mL in iodine measurement and 0.64 mg/mL in bismuth measurement. In the pig study, the enhancing bowel wall containing iodine and the small bowel loop containing bismuth were not differentiable in the original PCD-CT images. However, they were clearly distinctive from each other in the iodine- and bismuth-specific images after material decomposition, as reviewed by an abdominal radiologist. In addition, quantitative analysis showed that the misclassification between the two contrast materials was less than 1.0 mg/mL. Conclusions Our study demonstrated the feasibility of simultaneous imaging of iodine and bismuth in small bowel of swine using PCD-CT.
KW - contrast materials
KW - material decomposition
KW - multi-energy CT (MECT)
KW - photon-counting-detector (PCD)
UR - http://www.scopus.com/inward/record.url?scp=85090506970&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85090506970&partnerID=8YFLogxK
U2 - 10.1097/RLI.0000000000000687
DO - 10.1097/RLI.0000000000000687
M3 - Article
C2 - 32530868
AN - SCOPUS:85090506970
SN - 0020-9996
VL - 55
SP - 688
EP - 694
JO - Investigative Radiology
JF - Investigative Radiology
IS - 10
ER -