TY - JOUR
T1 - Real-Time Whole-Brain Radiation Therapy
T2 - A Single-Institution Experience
AU - Le, Anh H.
AU - Stojadinovic, Strahinja
AU - Timmerman, Robert
AU - Choy, Hak
AU - Duncan, Romona L.
AU - Jiang, Steve B.
AU - Pompos, Arnold
N1 - Publisher Copyright:
© 2018
PY - 2018/4/1
Y1 - 2018/4/1
N2 - Purpose: To demonstrate the feasibility of a real-time whole-brain radiation therapy (WBRT) workflow, taking advantage of contemporary radiation therapy capabilities and seeking to optimize clinical workflow for WBRT. Methods and Materials: We developed a method incorporating the linear accelerator's on-board imaging system for patient simulation, used cone-beam computed tomography (CBCT) data for treatment planning, and delivered the first fraction of prescribed therapy, all during the patient's initial appointment. Simulation was performed in the linear accelerator vault. An acquired CBCT data set was used for scripted treatment planning protocol, providing inversely planned, automated treatment plan generation. The osseous boundaries of the brain were auto-contoured to create a target volume. Two parallel-opposed beams using field-in-field intensity modulate radiation therapy covered this target to the user-defined inferior level (C1 or C2). The method was commissioned using an anthropomorphic head phantom and verified using 100 clinically treated patients. Results: Whole-brain target heterogeneity was within 95%-107% of the prescription dose, and target coverage compared favorably to standard, manually created 3-dimensional plans. For the commissioning CBCT datasets, the secondary monitor unit verification and independent 3-dimensional dose distribution comparison for computed and delivered doses were within 2% agreement relative to the scripted auto-plans. On average, time needed to complete the entire process was 35.1 ± 10.3 minutes from CBCT start to last beam delivered. Conclusions: The real-time WBRT workflow using integrated on-site imaging, planning, quality assurance, and delivery was tested and deemed clinically feasible. The design necessitates a synchronized team consisting of physician, physicist, dosimetrist, and therapists. This work serves as a proof of concept of real-time planning and delivery for other treatment sites.
AB - Purpose: To demonstrate the feasibility of a real-time whole-brain radiation therapy (WBRT) workflow, taking advantage of contemporary radiation therapy capabilities and seeking to optimize clinical workflow for WBRT. Methods and Materials: We developed a method incorporating the linear accelerator's on-board imaging system for patient simulation, used cone-beam computed tomography (CBCT) data for treatment planning, and delivered the first fraction of prescribed therapy, all during the patient's initial appointment. Simulation was performed in the linear accelerator vault. An acquired CBCT data set was used for scripted treatment planning protocol, providing inversely planned, automated treatment plan generation. The osseous boundaries of the brain were auto-contoured to create a target volume. Two parallel-opposed beams using field-in-field intensity modulate radiation therapy covered this target to the user-defined inferior level (C1 or C2). The method was commissioned using an anthropomorphic head phantom and verified using 100 clinically treated patients. Results: Whole-brain target heterogeneity was within 95%-107% of the prescription dose, and target coverage compared favorably to standard, manually created 3-dimensional plans. For the commissioning CBCT datasets, the secondary monitor unit verification and independent 3-dimensional dose distribution comparison for computed and delivered doses were within 2% agreement relative to the scripted auto-plans. On average, time needed to complete the entire process was 35.1 ± 10.3 minutes from CBCT start to last beam delivered. Conclusions: The real-time WBRT workflow using integrated on-site imaging, planning, quality assurance, and delivery was tested and deemed clinically feasible. The design necessitates a synchronized team consisting of physician, physicist, dosimetrist, and therapists. This work serves as a proof of concept of real-time planning and delivery for other treatment sites.
UR - http://www.scopus.com/inward/record.url?scp=85041585590&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85041585590&partnerID=8YFLogxK
U2 - 10.1016/j.ijrobp.2017.12.282
DO - 10.1016/j.ijrobp.2017.12.282
M3 - Article
C2 - 29397212
AN - SCOPUS:85041585590
SN - 0360-3016
VL - 100
SP - 1280
EP - 1288
JO - International Journal of Radiation Oncology Biology Physics
JF - International Journal of Radiation Oncology Biology Physics
IS - 5
ER -