TY - JOUR
T1 - Predictors of adequate ultrasound quality for hepatocellular carcinoma surveillance in patients with cirrhosis
AU - Simmons, O.
AU - Fetzer, D. T.
AU - Yokoo, T.
AU - Marrero, J. A.
AU - Yopp, A.
AU - Kono, Y.
AU - Parikh, N. D.
AU - Browning, T.
AU - Singal, A. G.
N1 - Funding Information:
Declaration of personal interests: None. Declaration of funding interests: This study was conducted with support from AHRQ Center for Patient-Centered Outcomes Research (R24 HS022418) and CPRIT (CPRIT R15-MIRA-2). The content is solely the responsibility of the authors and does not necessarily represent the official views of the National Institutes of Health or the American Cancer Society.
Publisher Copyright:
© 2016 John Wiley & Sons Ltd
PY - 2017/1/1
Y1 - 2017/1/1
N2 - Background: Abdominal ultrasound fails to detect over one-fourth of hepatocellular carcinoma (HCC) at an early stage in patients with cirrhosis. Identifying patients in whom ultrasound is of inadequate quality can inform interventions to improve surveillance effectiveness. Aim: To evaluate and identify predictors of ultrasound quality in patients with cirrhosis. Methods: We performed a retrospective cohort study among patients who underwent ultrasound examination for a cirrhosis-related indication between April 2015 and October 2015. Three fellowship-trained abdominal radiologists collectively reviewed all ultrasound exams and categorised exam quality as definitely adequate, likely adequate, likely inadequate and definitely inadequate to exclude liver lesions. We performed multivariable logistic regression to determine characteristics associated with inadequate ultrasound quality. Results: Among 941 patients, 191 (20.3%) ultrasounds were inadequate for excluding HCC- 134 definitely inadequate and 57 likely inadequate. In multivariable analysis, inadequate quality was associated with male gender (OR 1.68, 95% CI 1.14–2.48), body mass index category (OR 1.67, 95% CI 1.45–1.93), Child–Pugh B or C cirrhosis (OR 1.93, 95% CI 1.32–2.81), alcohol-related cirrhosis (OR 2.11, 95% CI 1.33–3.37), NASH cirrhosis (OR 2.87, 95% CI 1.71–4.80), and in-patient status (OR 1.55, 95% CI 1.01–2.37). Ultrasounds were inadequate in over one-third of patients with Child–Pugh C cirrhosis, BMI >35, or NASH cirrhosis. Conclusions: One in five ultrasounds in patients with cirrhosis are inadequate for exclusion of HCC, which can contribute to surveillance failure. Alternative surveillance modalities are needed in subgroups prone to inadequate ultrasounds including obese patients, those with Child Pugh B or C cirrhosis, and those with alcohol- or NASH-related cirrhosis.
AB - Background: Abdominal ultrasound fails to detect over one-fourth of hepatocellular carcinoma (HCC) at an early stage in patients with cirrhosis. Identifying patients in whom ultrasound is of inadequate quality can inform interventions to improve surveillance effectiveness. Aim: To evaluate and identify predictors of ultrasound quality in patients with cirrhosis. Methods: We performed a retrospective cohort study among patients who underwent ultrasound examination for a cirrhosis-related indication between April 2015 and October 2015. Three fellowship-trained abdominal radiologists collectively reviewed all ultrasound exams and categorised exam quality as definitely adequate, likely adequate, likely inadequate and definitely inadequate to exclude liver lesions. We performed multivariable logistic regression to determine characteristics associated with inadequate ultrasound quality. Results: Among 941 patients, 191 (20.3%) ultrasounds were inadequate for excluding HCC- 134 definitely inadequate and 57 likely inadequate. In multivariable analysis, inadequate quality was associated with male gender (OR 1.68, 95% CI 1.14–2.48), body mass index category (OR 1.67, 95% CI 1.45–1.93), Child–Pugh B or C cirrhosis (OR 1.93, 95% CI 1.32–2.81), alcohol-related cirrhosis (OR 2.11, 95% CI 1.33–3.37), NASH cirrhosis (OR 2.87, 95% CI 1.71–4.80), and in-patient status (OR 1.55, 95% CI 1.01–2.37). Ultrasounds were inadequate in over one-third of patients with Child–Pugh C cirrhosis, BMI >35, or NASH cirrhosis. Conclusions: One in five ultrasounds in patients with cirrhosis are inadequate for exclusion of HCC, which can contribute to surveillance failure. Alternative surveillance modalities are needed in subgroups prone to inadequate ultrasounds including obese patients, those with Child Pugh B or C cirrhosis, and those with alcohol- or NASH-related cirrhosis.
UR - http://www.scopus.com/inward/record.url?scp=84999036821&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84999036821&partnerID=8YFLogxK
U2 - 10.1111/apt.13841
DO - 10.1111/apt.13841
M3 - Article
C2 - 27862091
AN - SCOPUS:84999036821
SN - 0269-2813
VL - 45
SP - 169
EP - 177
JO - Alimentary Pharmacology and Therapeutics
JF - Alimentary Pharmacology and Therapeutics
IS - 1