TY - JOUR
T1 - Optical coherence tomography analysis of the stenting of saphenous vein graft (SOS) xience v study
T2 - Use of the everolimus-eluting stent in saphenous vein graft lesions
AU - Papayannis, Aristotelis C.
AU - Michael, Tesfaldet T.
AU - Yangirova, Dinara
AU - Abdel-Karim, Abdul Rahman
AU - Kohlhaas, Julia
AU - Mahmood, Arif
AU - Addo, Tayo
AU - Haagen, Donald
AU - Makke, Lorenza
AU - Roesle, Michele
AU - Rangan, Bavana
AU - Banerjee, Subhash
AU - Brilakis, Emmanouil S.
PY - 2012/8/1
Y1 - 2012/8/1
N2 - Objectives: The Stenting of Saphenous Grafts-Xience V (SOS-Xience V) trial prospectively examined the frequency of angiographic in-stent restenosis in saphenous vein graft (SVG) lesions 12 months after implantation of a Xience V everolimus-eluting stent (EES; Abbott Vascular). Optical coherence tomography (OCT) during follow-up angiography was added to the protocol after OCT was approved for clinical use in the United States. Methods: Forty patients with 40 SVG lesions were enrolled in the study, of whom 27 underwent 12-month coronary angiography and 12 (only 1 of whom had in-stent restenosis) also had follow-up OCT evaluation. OCT strut-level analysis was performed to determine the percentage of strut coverage, malapposition, strut protrusion, neointimal thickness, and the existence of thrombus. Results: Mean patient age was 67 ± 7 years, and 95% were men. A total of 2584 struts were evaluated by OCT. The percentages for uncovered, malapposed, and protruding struts were 4%, 9%, and 15%, respectively. The mean strut neointimal thickness was 0.094 ± 0.094 mm. Of the 12 stents analyzed, 4 (33%) showed full neointimal coverage, 2 (17%) had all the struts embedded, 7 (58%) had at least 1 malapposed strut, and 10 (83%) had at least 1 protruding strut. The mean difference between the stent area and the lumen area was 0.36 ± 1.6 mm. No thrombus was detected in the stented areas. CONCLUSIONS: Use of EES in SVGs is associated with high rates of stent strut coverage and high malapposition rates at 12 months post implantation.
AB - Objectives: The Stenting of Saphenous Grafts-Xience V (SOS-Xience V) trial prospectively examined the frequency of angiographic in-stent restenosis in saphenous vein graft (SVG) lesions 12 months after implantation of a Xience V everolimus-eluting stent (EES; Abbott Vascular). Optical coherence tomography (OCT) during follow-up angiography was added to the protocol after OCT was approved for clinical use in the United States. Methods: Forty patients with 40 SVG lesions were enrolled in the study, of whom 27 underwent 12-month coronary angiography and 12 (only 1 of whom had in-stent restenosis) also had follow-up OCT evaluation. OCT strut-level analysis was performed to determine the percentage of strut coverage, malapposition, strut protrusion, neointimal thickness, and the existence of thrombus. Results: Mean patient age was 67 ± 7 years, and 95% were men. A total of 2584 struts were evaluated by OCT. The percentages for uncovered, malapposed, and protruding struts were 4%, 9%, and 15%, respectively. The mean strut neointimal thickness was 0.094 ± 0.094 mm. Of the 12 stents analyzed, 4 (33%) showed full neointimal coverage, 2 (17%) had all the struts embedded, 7 (58%) had at least 1 malapposed strut, and 10 (83%) had at least 1 protruding strut. The mean difference between the stent area and the lumen area was 0.36 ± 1.6 mm. No thrombus was detected in the stented areas. CONCLUSIONS: Use of EES in SVGs is associated with high rates of stent strut coverage and high malapposition rates at 12 months post implantation.
KW - coronary artery bypass graft surgery
KW - drug-eluting stents
KW - optical coherence tomography
KW - percutaneous coronary intervention
KW - saphenous vein grafts
UR - http://www.scopus.com/inward/record.url?scp=84865130309&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84865130309&partnerID=8YFLogxK
M3 - Article
C2 - 22865309
AN - SCOPUS:84865130309
SN - 1042-3931
VL - 24
SP - 390
EP - 394
JO - Journal of Invasive Cardiology
JF - Journal of Invasive Cardiology
IS - 8
ER -