In vitro hemocompatibility studies of drug-loaded poly-(L-lactic acid) fibers

K. T. Nguyen, S. H. Su, A. Sheng, D. Wawro, N. D. Schwade, C. F. Brouse, P. E. Greilich, L. Tang, R. C. Eberhart

Research output: Contribution to journalArticlepeer-review

61 Scopus citations

Abstract

Our objective was to evaluate the hemocompatibility of biodegradable stent fibers, employing a closed-loop circulation system filled with human blood. We also investigated the effects of the anti-inflammatory and anti-proliferative drugs curcumin and paclitaxel, incorporated into stent fibers. Fresh whole blood was circulated in four parallel closed-loop systems: the empty tube circuit (control) and tubes containing either a PLLA fiber coil (PLLA), a curcumin-loaded PLLA coil (C-PLLA) or a paclitaxel-loaded PLLA coil (P-PLLA). The influence of PLLA fiber, alone or loaded with drug incorporated during melt-extrusion, on leukocyte and platelet adhesion and activation was determined by flow cytometry. The effects of blood flow and fiber properties on cell deposition were assessed by scanning electron microscopy (SEM). The flow cytometry results clearly demonstrated that PLLA triggers blood cell activation at the site of deployment, as shown by increases in CD11b, CD62P and leukocyte-platelet aggregates, compared to controls. Curcumin and paclitaxel treatments both significantly reduced leukocyte and platelet activation and adhesion to PLLA fibers, as shown by flow cytometry and SEM. Activated leukocytes and platelets revealed significantly lower CD11b and CD62P receptor binding for C-PLLA compared with PLLA alone, and slightly lower for P-PLLA. Reductions in platelet-leukocyte aggregates were observed as well. In addition, there was less leukocyte and platelet adhesion to C-PLLA, compared with PLLA fiber controls, as shown by SEM. A continuous linear thrombus, composed of platelets, leukocytes, red blood cells and fibrin was occasionally detected along the line of tangency between the coil and the tube wall. Flow separation and eddying, proximal and distal to the line of tangency of coil and tube, is thought to contribute to this deposit. Curcumin was more effective than paclitaxel in reducing leukocyte and platelet activation and adhesion to PLLA stent fibers in this setting. However there was evidence of paclitaxel degeneration during melt extrusion that may have inhibited its effectiveness. Incorporation of the anti-inflammatory and anti-proliferative drug curcumin into bioresorbable stent fibers is proposed to prevent thrombosis and in-stent restenosis.

Original languageEnglish (US)
Pages (from-to)5191-5201
Number of pages11
JournalBiomaterials
Volume24
Issue number28
DOIs
StatePublished - Dec 2003

Keywords

  • Curcumin
  • Hemocompatibility
  • In vitro whole blood circulation model
  • Inflammatory response
  • Paclitaxel
  • Poly-(L-lactic acid)

ASJC Scopus subject areas

  • Bioengineering
  • Ceramics and Composites
  • Biophysics
  • Biomaterials
  • Mechanics of Materials

Fingerprint

Dive into the research topics of 'In vitro hemocompatibility studies of drug-loaded poly-(L-lactic acid) fibers'. Together they form a unique fingerprint.

Cite this