@article{6b9c9258db9d477ab5f0d577799e1d1c,
title = "Evaluation of a novel rule-out myocardial infarction protocol incorporating high-sensitivity troponin T in a US hospital",
keywords = "Myocardial infarction, Sensitivity, Specificity, Troponin",
author = "Rebecca Vigen and Patricia Kutscher and Fernabelle Fernandez and Amy Yu and Bryan Bertulfo and Hashim, {Ibrahim A} and Molberg, {Kyle H} and Deborah Diercks and Metzger, {Jeffery C.} and Jose Soto and Dergham Alzubaidy and Lorie Thibodeaux and Joglar, {Jose A} and {de Lemos}, {James A} and Das, {Sandeep R}",
note = "Funding Information: Dr Vigen was supported by the National Center for Advancing Translational Sciences of the National Institutes of Health under award UL1TR001105. The content is solely the responsibility of the authors and does not necessarily represent the official views of the National Institutes of Health. Funding Information: Dr Diercks reports consulting income from Roche Diagnostics, and consulting income and research support from Siemens Diagnostics. Dr de Lemos reports grant support from Roche Diagnostics and Abbott Diagnostics and consulting income from Roche Diagnostics, Abbott Diagnostics, Ortho Clinical Diagnostics, and Endpoint Committees for Radiometer and Siemen{\textquoteright}s Health Care Diagnostics. Dr Das reports consulting income from Roche Diagnostics. The other authors report no conflicts.",
year = "2018",
doi = "10.1161/CIRCULATIONAHA.118.033861",
language = "English (US)",
volume = "138",
pages = "2061--2063",
journal = "Circulation",
issn = "0009-7322",
publisher = "Lippincott Williams and Wilkins",
number = "18",
}