TY - JOUR
T1 - Estimation and reduction of decorrelation effect due to tissue lateral displacement in elastography
AU - Bai, Jing
AU - Ding, Chuxiong
AU - Luo, Jianwen
AU - He, Ping
N1 - Funding Information:
This work is supported in part by the National Natural Science Foundation of China.
PY - 2002/5
Y1 - 2002/5
N2 - In cross-correlation based elastography, the quality of the strain image is degraded by the distortion of echo waveforms due to tissue axial and lateral displacement. To study the effects of tissue lateral displacement on echo decorrelation, a tissue axial stretching model is developed and a concept called correlation signal-to-noise ratio (CSNR) is introduced to quantify the decorrelation effect due to tissue lateral displacement. A computer simulation based on the tissue stretching model is carried out to study the influence of several important elastographic parameters on echo decorrelation due to tissue lateral displacement. Finally, guided by the CSNR concept, a 2-dimensional (D) spatial comprehensive cross-correlation method is proposed to reduce the decorrelation noise. Results indicate that CSNR can be used as a quality indicator of elastography and the 2-D spatial comprehensive cross-correlation method can effectively reduce the decorrelation noise while slightly decreasing the lateral resolution of the strain image.
AB - In cross-correlation based elastography, the quality of the strain image is degraded by the distortion of echo waveforms due to tissue axial and lateral displacement. To study the effects of tissue lateral displacement on echo decorrelation, a tissue axial stretching model is developed and a concept called correlation signal-to-noise ratio (CSNR) is introduced to quantify the decorrelation effect due to tissue lateral displacement. A computer simulation based on the tissue stretching model is carried out to study the influence of several important elastographic parameters on echo decorrelation due to tissue lateral displacement. Finally, guided by the CSNR concept, a 2-dimensional (D) spatial comprehensive cross-correlation method is proposed to reduce the decorrelation noise. Results indicate that CSNR can be used as a quality indicator of elastography and the 2-D spatial comprehensive cross-correlation method can effectively reduce the decorrelation noise while slightly decreasing the lateral resolution of the strain image.
UR - http://www.scopus.com/inward/record.url?scp=0036557922&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0036557922&partnerID=8YFLogxK
U2 - 10.1109/TUFFC.2002.1002452
DO - 10.1109/TUFFC.2002.1002452
M3 - Article
C2 - 12046929
AN - SCOPUS:0036557922
SN - 0885-3010
VL - 49
SP - 541
EP - 549
JO - IRE Transactions on Ultrasonic Engineering
JF - IRE Transactions on Ultrasonic Engineering
IS - 5
ER -