TY - JOUR
T1 - Enhancing lipoaspirate efficiency by altering liposuction cannula design
AU - Beck, Daniel O.
AU - Davis, Kathryn
AU - Rohrich, Rod J.
N1 - Funding Information:
Disclosure: Dr. Rohrich receives instrument royalties from Micrins, Inc. (Eriem Surgical, Lake Forest, Ill.) and publishing royalties from Quality Medical Publishing, Inc. (St. Louis, Miss.). Neither of the other authors has any financial disclosures. This study was supported by the Department of Plastic Surgery at the University of Texas Southwestern Medical Center, Dallas Tex. The Article Processing Charge was paid for by the authors.
Publisher Copyright:
Copyright © 2014 The Authors.
PY - 2014
Y1 - 2014
N2 - Background: Interplay between the components of a lipoplasty system (suction pump, suction tubing, collection canister, and cannula) determines liposuction efficiency. However, in clinical practice, none of the components are more important than the cannula. Cannula design including port design, port placement, and shaft characteristics is the single most influential contributor to flow resistance and dramatically effects speed of aspiration and final contour. Many variations on port design and placement are available, yet functional enhancements to the cannula shaft have largely been ignored. We have engineered a set of novel cannulas addressing vital elements of cannula design in the effort to enhance aspiration efficiency and efficacy. Methods: Two novel cannula designs (dual- and multiport, in-line configuration), created using a unique proprietary manufacturing process, were evaluated against a popular industry standard design (tri-port, Mercedes configuration) to assess aspiration efficiency. Cannulas with shaft diameters of 3, 4, and 5 mm were attached to a standardized lipoplasty system and evaluated in real time for their ability to aspirate a viscous applesauce medium over a 5-minute time course. For each cannula, we calculated (1) the cross-sectional area of the cannula shaft, (2) single and total port area, (3) port-to-shaft ratio, and (4) theoretical resistance. Results: The relationship between the cannula shaft and cannula port(s) directly influenced flow dynamics. Comparing medium uptake time, aspiration efficiency and the aspiration curves demonstrated a significant improvement of the 2 novel cannulas over the standard cannula in the 5- and 4-mm designations. In the 3-mm group, a difference in uptake time remained. However, a significant difference in aspiration efficiency was only seen between the dual-port novel cannula and tri-port Mercedes standard cannula. Further, differences in the aspiration curves between all 3-mm cannulas approached but did not reach significance. Conclusions: We have developed 2 novel cannulas that maximize port features and seek to minimize the internal shaft resistance. Both designs demonstrate enhanced aspiration and uptake compared with an industry standard design.
AB - Background: Interplay between the components of a lipoplasty system (suction pump, suction tubing, collection canister, and cannula) determines liposuction efficiency. However, in clinical practice, none of the components are more important than the cannula. Cannula design including port design, port placement, and shaft characteristics is the single most influential contributor to flow resistance and dramatically effects speed of aspiration and final contour. Many variations on port design and placement are available, yet functional enhancements to the cannula shaft have largely been ignored. We have engineered a set of novel cannulas addressing vital elements of cannula design in the effort to enhance aspiration efficiency and efficacy. Methods: Two novel cannula designs (dual- and multiport, in-line configuration), created using a unique proprietary manufacturing process, were evaluated against a popular industry standard design (tri-port, Mercedes configuration) to assess aspiration efficiency. Cannulas with shaft diameters of 3, 4, and 5 mm were attached to a standardized lipoplasty system and evaluated in real time for their ability to aspirate a viscous applesauce medium over a 5-minute time course. For each cannula, we calculated (1) the cross-sectional area of the cannula shaft, (2) single and total port area, (3) port-to-shaft ratio, and (4) theoretical resistance. Results: The relationship between the cannula shaft and cannula port(s) directly influenced flow dynamics. Comparing medium uptake time, aspiration efficiency and the aspiration curves demonstrated a significant improvement of the 2 novel cannulas over the standard cannula in the 5- and 4-mm designations. In the 3-mm group, a difference in uptake time remained. However, a significant difference in aspiration efficiency was only seen between the dual-port novel cannula and tri-port Mercedes standard cannula. Further, differences in the aspiration curves between all 3-mm cannulas approached but did not reach significance. Conclusions: We have developed 2 novel cannulas that maximize port features and seek to minimize the internal shaft resistance. Both designs demonstrate enhanced aspiration and uptake compared with an industry standard design.
UR - http://www.scopus.com/inward/record.url?scp=85007307478&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85007307478&partnerID=8YFLogxK
U2 - 10.1097/GOX.0000000000000101
DO - 10.1097/GOX.0000000000000101
M3 - Article
C2 - 25426339
AN - SCOPUS:85007307478
SN - 2169-7574
VL - 2
JO - Plastic and Reconstructive Surgery - Global Open
JF - Plastic and Reconstructive Surgery - Global Open
IS - 10
M1 - e222
ER -