T1 - Electrical Impedance Measurements of Biological Cells in Response to External Stimuli
AU - Mansoorifar, Amin
AU - Koklu, Anil
AU - Ma, Shihong
AU - Raj, Ganesh V.
AU - Beskok, Ali
N1 - Funding Information:
Research reported in this publication was supported by the National Institute of Arthritis and Musculoskeletal and Skin Diseases of the National Institute of Health (NIH) under Award Number R21AR063334. The content is solely the responsibility of the authors and does not necessarily represent the views of the NIH.
PY - 2018/4/3
Y1 - 2018/4/3
N2 - Dielectric spectroscopy (DS) is a noninvasive technique for real-time measurements of the impedance spectra of biological cells. DS enables characterization of cellular dielectric properties such as membrane capacitance and cytoplasmic conductivity. We have developed a lab-on-a-chip device that uses an electro-activated microwells array for capturing, DS measurements, and unloading of biological cells. Impedance measurements were conducted at 0.2 V in the 10 kHz to 40 MHz range with 6 s time resolution. An equivalent circuit model was developed to extract the cell membrane capacitance and cell cytoplasmic conductivity from the impedance spectra. A human prostate cancer cell line, PC-3, was used to evaluate the device performance. Suspension of PC-3 cells in low conductivity buffers (LCB) enhanced their dielectrophoretic trapping and impedance response. We report the time course of the variations in dielectric properties of PC-3 cells suspended in LCB and their response to sudden pH change from a pH of 7.3 to a pH of 5.8. Importantly, we demonstrated that our device enabled real-time measurements of dielectric properties of live cancer cells and allowed the assessment of the cellular response to variations in buffer conductivity and pH. These data support further development of this device toward single cell measurements.
AB - Dielectric spectroscopy (DS) is a noninvasive technique for real-time measurements of the impedance spectra of biological cells. DS enables characterization of cellular dielectric properties such as membrane capacitance and cytoplasmic conductivity. We have developed a lab-on-a-chip device that uses an electro-activated microwells array for capturing, DS measurements, and unloading of biological cells. Impedance measurements were conducted at 0.2 V in the 10 kHz to 40 MHz range with 6 s time resolution. An equivalent circuit model was developed to extract the cell membrane capacitance and cell cytoplasmic conductivity from the impedance spectra. A human prostate cancer cell line, PC-3, was used to evaluate the device performance. Suspension of PC-3 cells in low conductivity buffers (LCB) enhanced their dielectrophoretic trapping and impedance response. We report the time course of the variations in dielectric properties of PC-3 cells suspended in LCB and their response to sudden pH change from a pH of 7.3 to a pH of 5.8. Importantly, we demonstrated that our device enabled real-time measurements of dielectric properties of live cancer cells and allowed the assessment of the cellular response to variations in buffer conductivity and pH. These data support further development of this device toward single cell measurements.
UR - http://www.scopus.com/inward/record.url?scp=85044995137&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85044995137&partnerID=8YFLogxK
U2 - 10.1021/acs.analchem.7b05392
DO - 10.1021/acs.analchem.7b05392
M3 - Article
C2 - 29402081
AN - SCOPUS:85044995137
SN - 0003-2700
VL - 90
SP - 4320
EP - 4327
JO - Analytical Chemistry
JF - Analytical Chemistry
IS - 7
ER -