T1 - Effect of EKG Sampling Rate on Heart Rate Variability Analysis
AU - Govindan, R. B.
AU - Massaro, An N.
AU - Kota, Srinivas
AU - Grabowski, Reagan C.
AU - Wilson, James D.
AU - Plessis, Adre Du
N1 - Funding Information:
Research supported by American Heart Association.
Publisher Copyright:
© 2019 IEEE.
PY - 2019/7
Y1 - 2019/7
N2 - We studied the effect of EKG sampling rate on heart rate variability (HRV) analysis. We acquired EKG from four term hypoxic-ischemic encephalopathic infants undergoing therapeutic hypothermia. The EKG signal was acquired continuously for 4 days from the cardiorespiratory monitor through the analog port. The following HRV metrics were calculated: normalized low-frequency (nLF), normalized high-frequency (nHF), low-frequency (LF), high-frequency (HF), short-term detrended fluctuation analysis (DFA) exponent (αs), long-term DFA exponent (αL), root mean square (RMS) short (RMSS), and RMS long (RMSL). In addition, heart rate was used. These metrics were calculated for EKG acquired at 1 KHz (served as reference, EKGref) as well as from EKGs downsampled at 500 Hz (EKG500), 250 Hz (EKG250), and 125 Hz (EKG125). The bedside monitors were simultaneously sending the EKG to a data warehouse, storing the EKG (EKGDWH) at 250 Hz. All HRV metrics were also calculated for the EKGDWH. The comparison between HRV metrics calculated from EKGref and downsampled EKG (EKG500, EKG250, EKG125) was made with intraclass correlation coefficient (r). The comparisons of HRV metrics between EKG250 and EKGDWH were also made with ICC. Our results show that HRV calculated with EKGref and from downsampled EKG were highly correlated (r>0.8 for all comparisons, P<0.001). HRV metrics from EKG250 and EKGDWH were also significantly correlated (r=0.7, P<0.001) for all metrics except for HF (r=0.276). These data show that HF power is compromised in the EKGDWH signal and caution must be exercised in interpreting the HF power calculated from this EKG.
AB - We studied the effect of EKG sampling rate on heart rate variability (HRV) analysis. We acquired EKG from four term hypoxic-ischemic encephalopathic infants undergoing therapeutic hypothermia. The EKG signal was acquired continuously for 4 days from the cardiorespiratory monitor through the analog port. The following HRV metrics were calculated: normalized low-frequency (nLF), normalized high-frequency (nHF), low-frequency (LF), high-frequency (HF), short-term detrended fluctuation analysis (DFA) exponent (αs), long-term DFA exponent (αL), root mean square (RMS) short (RMSS), and RMS long (RMSL). In addition, heart rate was used. These metrics were calculated for EKG acquired at 1 KHz (served as reference, EKGref) as well as from EKGs downsampled at 500 Hz (EKG500), 250 Hz (EKG250), and 125 Hz (EKG125). The bedside monitors were simultaneously sending the EKG to a data warehouse, storing the EKG (EKGDWH) at 250 Hz. All HRV metrics were also calculated for the EKGDWH. The comparison between HRV metrics calculated from EKGref and downsampled EKG (EKG500, EKG250, EKG125) was made with intraclass correlation coefficient (r). The comparisons of HRV metrics between EKG250 and EKGDWH were also made with ICC. Our results show that HRV calculated with EKGref and from downsampled EKG were highly correlated (r>0.8 for all comparisons, P<0.001). HRV metrics from EKG250 and EKGDWH were also significantly correlated (r=0.7, P<0.001) for all metrics except for HF (r=0.276). These data show that HF power is compromised in the EKGDWH signal and caution must be exercised in interpreting the HF power calculated from this EKG.
UR - http://www.scopus.com/inward/record.url?scp=85068179188&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85068179188&partnerID=8YFLogxK
U2 - 10.1109/EMBC.2019.8857754
DO - 10.1109/EMBC.2019.8857754
M3 - Conference contribution
C2 - 31947397
AN - SCOPUS:85068179188
T3 - Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBS
SP - 6780
EP - 6783
BT - 2019 41st Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBC 2019
PB - Institute of Electrical and Electronics Engineers Inc.
T2 - 41st Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBC 2019
Y2 - 23 July 2019 through 27 July 2019
ER -