TY - GEN
T1 - Data-driven detection of adverse events in robotic needle steering
AU - Narayan, Meenakshi
AU - Fey, Ann Majewicz
AU - Choti, Michael A.
N1 - Funding Information:
Fig. 1: Fluoroscopic images of a steerable needle inserted into a porcine cadaver liver. This pilot study was conducted in the Zeego Imaging Lab at Stanford University (NIH S10 Shared Instrumentation Grant, S10RR026714-01).
Publisher Copyright:
© 2018 IEEE.
PY - 2018/4/6
Y1 - 2018/4/6
N2 - In robotic needle steering, adverse events such as needle buckling, undesired curvature changes, and tissue displacement can occur during needle insertions into tissue, preventing accurate needle placement. This paper focuses on detecting tissue displacement and needle curvature changes using data-driven detection algorithms, informed solely by needle and tissue position measurements. The algorithms were evaluated for different needle insertion velocities and duty-cycles, and analyzed using a Kruskal-Wallis statistical test. Results show that with increased insertion velocity, tissues displace sooner (p <0.01), while duty-cycles have no effect. Furthermore, with increased insertion velocity and lower duty-cycles, the needle curvature radius decreases (p <0.01). Additionally, the algorithms were evaluated for needle insertions into ex vivo liver tissue, under live fluoroscopic imaging. The goal of this study was to evaluate the effects of constrained or unconstrained boundary conditions on adverse events. As expected, unconstrained tissue experienced more displacement events. Fluoroscopic videos confirmed accurate and timely prediction of the adverse events. Finally, these algorithms were designed to detect multiple adverse events, simultaneously, and can be implemented in real time.
AB - In robotic needle steering, adverse events such as needle buckling, undesired curvature changes, and tissue displacement can occur during needle insertions into tissue, preventing accurate needle placement. This paper focuses on detecting tissue displacement and needle curvature changes using data-driven detection algorithms, informed solely by needle and tissue position measurements. The algorithms were evaluated for different needle insertion velocities and duty-cycles, and analyzed using a Kruskal-Wallis statistical test. Results show that with increased insertion velocity, tissues displace sooner (p <0.01), while duty-cycles have no effect. Furthermore, with increased insertion velocity and lower duty-cycles, the needle curvature radius decreases (p <0.01). Additionally, the algorithms were evaluated for needle insertions into ex vivo liver tissue, under live fluoroscopic imaging. The goal of this study was to evaluate the effects of constrained or unconstrained boundary conditions on adverse events. As expected, unconstrained tissue experienced more displacement events. Fluoroscopic videos confirmed accurate and timely prediction of the adverse events. Finally, these algorithms were designed to detect multiple adverse events, simultaneously, and can be implemented in real time.
KW - Data-driven detection
KW - adverse events
KW - robotic needle steering
KW - tissue displacement
UR - http://www.scopus.com/inward/record.url?scp=85050586142&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85050586142&partnerID=8YFLogxK
U2 - 10.1109/ISMR.2018.8333297
DO - 10.1109/ISMR.2018.8333297
M3 - Conference contribution
AN - SCOPUS:85050586142
T3 - 2018 International Symposium on Medical Robotics, ISMR 2018
SP - 1
EP - 6
BT - 2018 International Symposium on Medical Robotics, ISMR 2018
PB - Institute of Electrical and Electronics Engineers Inc.
T2 - 2018 International Symposium on Medical Robotics, ISMR 2018
Y2 - 1 March 2018 through 3 March 2018
ER -