TY - JOUR
T1 - Correlating Quantitative Para-Aortic Lymph Node Computed Tomography Parameters with Fluorodeoxyglucose Positron Emission Tomography for Cervical Cancer Staging
T2 - Possible Solution for Resource Constrained Countries
AU - D'Cunha, Paul
AU - Albuquerque, Kevin
AU - Xi, Yin
AU - Pinho, Daniella F
N1 - Publisher Copyright:
© Wolters Kluwer Health, Inc. All rights reserved.
PY - 2022/7/1
Y1 - 2022/7/1
N2 - Objective The aim of the study was to determine the most accurate quantitative morphological parameters on computed tomography (CT) that correlate with fluorodeoxyglucose (FDG)-avid para-aortic nodes (PANs) in patients with cervical cancer. Methods A single-institution retrospective evaluation was performed of women with cervical cancer who underwent pretreatment positron emission tomography (PET)/CT and radiotherapy therapy planning CT between 2009 and 2020. A node-by-node correlation between pretreatment CT and PET/CT was performed for the reference standard of FDG avidity for short- and long-axis diameters, volume, and long-/short-axis ratio (L/S). The FDG-avid PANs were defined as PET-positive and non-FDG-avid PANs from patients without PET-determined PAN metastasis were defined as PET negative. Area under the receiver operator curve was calculated to access diagnostic accuracy of the different quantitative parameters. Results A total of 94 women (mean age ± standard deviation, 52 ± 13 years) with cervical cancer were included. Forty-seven patients had PET-positive PANs (181 PET-positive PANs) and 47 patients had no PET-positive PANs (141 PET-negative PANs). The area under the receiver operator curve for volume (0.945) was greater (P < 0.001) than that of short axis (0.895), long axis (0.885), and L/S (0.583). At a specificity set point of 0.90 (127/141 PANs), the cutoff for volume was 0.443 cm3 or greater (0.85 sensitivity [154/181 PANs]; 95% confidence interval, 0.83-0.93) and for short-axis diameter was 5.9 mm or greater (0.75 sensitivity [135/181 PANs]; 95% confidence interval, 0.68-0.81). Conclusions Para-aortic lymph node volume demonstrated that improved node-by-node correlation between CT and PET/CT compared with short-axis diameter, long-axis diameter, and L/S and is an alternative to improve detection of PAN suspicious of metastatic diseases in locations without access to PET/CT.
AB - Objective The aim of the study was to determine the most accurate quantitative morphological parameters on computed tomography (CT) that correlate with fluorodeoxyglucose (FDG)-avid para-aortic nodes (PANs) in patients with cervical cancer. Methods A single-institution retrospective evaluation was performed of women with cervical cancer who underwent pretreatment positron emission tomography (PET)/CT and radiotherapy therapy planning CT between 2009 and 2020. A node-by-node correlation between pretreatment CT and PET/CT was performed for the reference standard of FDG avidity for short- and long-axis diameters, volume, and long-/short-axis ratio (L/S). The FDG-avid PANs were defined as PET-positive and non-FDG-avid PANs from patients without PET-determined PAN metastasis were defined as PET negative. Area under the receiver operator curve was calculated to access diagnostic accuracy of the different quantitative parameters. Results A total of 94 women (mean age ± standard deviation, 52 ± 13 years) with cervical cancer were included. Forty-seven patients had PET-positive PANs (181 PET-positive PANs) and 47 patients had no PET-positive PANs (141 PET-negative PANs). The area under the receiver operator curve for volume (0.945) was greater (P < 0.001) than that of short axis (0.895), long axis (0.885), and L/S (0.583). At a specificity set point of 0.90 (127/141 PANs), the cutoff for volume was 0.443 cm3 or greater (0.85 sensitivity [154/181 PANs]; 95% confidence interval, 0.83-0.93) and for short-axis diameter was 5.9 mm or greater (0.75 sensitivity [135/181 PANs]; 95% confidence interval, 0.68-0.81). Conclusions Para-aortic lymph node volume demonstrated that improved node-by-node correlation between CT and PET/CT compared with short-axis diameter, long-axis diameter, and L/S and is an alternative to improve detection of PAN suspicious of metastatic diseases in locations without access to PET/CT.
UR - http://www.scopus.com/inward/record.url?scp=85134297665&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85134297665&partnerID=8YFLogxK
U2 - 10.1097/RCT.0000000000001305
DO - 10.1097/RCT.0000000000001305
M3 - Article
C2 - 35405734
AN - SCOPUS:85134297665
SN - 0363-8715
VL - 46
SP - 551
EP - 559
JO - Journal of computer assisted tomography
JF - Journal of computer assisted tomography
IS - 4
ER -