Comparison of Efficacy and Complications of Cyclophotocoagulation and Second Glaucoma Drainage Device after Initial Glaucoma Drainage Device Failure

Margaret Y. Wang, Kishan Patel, Lauren S. Blieden, Alice Z. Chuang, Laura A. Baker, Nicholas P. Bell, Robert M. Feldman

Research output: Contribution to journalArticlepeer-review

18 Scopus citations

Abstract

Purpose: Compare intraocular pressure (IOP) control and complication rates of a second glaucoma drainage device (GDD) to diode transscleral cyclophotocoagulation (TSCPC) following failure of an initial GDD. Patients and Methods: Eyes with 1 GDD that required a second GDD or TSCPC for glaucoma control were included. Exclusion criteria were a cyclodestructive procedure before initial GDD, no light perception vision, or follow-up <1 year. Failure was defined as ≥1 of (1) reoperation for lowering IOP; (2) explantation of second GDD; (3) persistent hypotony; (4) use of oral carbonic anhydrase inhibitor for lowering IOP in the study eye; or (5) loss of light perception. Reoperation for lowering IOP included additional GDD implantation or additional cyclodestruction, except if additional cyclodestruction was within 6 months of the initial session. Results: A total of 75 eyes (35 in second GDD; 40 in TSCPC) were included (mean follow-up, 25.5 mo). Both procedures lowered IOP [-11.4 mm Hg (±13.6) for second GDD and-7.8 mm Hg (±11.8) for TSCPC groups] and decreased the number of IOP-lowering medications at the last visit. The second GDD group had significantly greater mean survival time [45.0 mo (±4.2)] than the TSCPC group [26.5 mo (±2.8)] but significantly more postoperative complications (60% of eyes) and non-IOP-related procedures (40% of eyes) than the TSCPC group (20% for postoperative complications and 18% for non-IOP-related procedures). Conclusions: Although both second procedures are efficacious in lowering IOP and number of IOP-lowering medications, TSCPC failed earlier, whereas a second GDD had significantly more complications.

Original languageEnglish (US)
Pages (from-to)1010-1018
Number of pages9
JournalJournal of Glaucoma
Volume26
Issue number11
DOIs
StatePublished - 2017
Externally publishedYes

Keywords

  • Key Words: Glaucoma drainage device
  • complications
  • glaucoma
  • intraocular pressure
  • transscleral diode cyclophotocoagulation

ASJC Scopus subject areas

  • Ophthalmology

Fingerprint

Dive into the research topics of 'Comparison of Efficacy and Complications of Cyclophotocoagulation and Second Glaucoma Drainage Device after Initial Glaucoma Drainage Device Failure'. Together they form a unique fingerprint.