Ad hoc versus standardized admixtures for continuous infusion drugs in neonatal intensive care: cognitive task analysis of safety at the bedside.

Research output: Contribution to journalArticlepeer-review

6 Scopus citations

Abstract

Continuous infusion intravenous (IV) drugs in neonatal intensive care are usually prepared based on patient weight so that the dose is readable as a simple multiple of the infusion pump rate. New safety guidelines propose that hospitals switch to using standardized admixtures of these drugs to prevent calculation errors during ad hoc preparation. Extended hierarchical task analysis suggests that switching to standardized admixtures may lead to more errors in programming the pump at the bedside.

Original languageEnglish (US)
Number of pages1
JournalAMIA ... Annual Symposium proceedings / AMIA Symposium. AMIA Symposium
StatePublished - 2006