Accuracy evaluation of using MV EPID and/or integrated kV imaging system to locate 3D positions of internal fiducial markers using a Calypso system

Weihua Mao, Ryan Foster, Timothy Solberg

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Abstract

Introduction: In order to use MV EPID and/or integrated kV imaging system to obtained 3D positions of implanted fiducial markers for the purpose of patient setup and/or image-guided radiation therapy in real-time, it is essential to investigate the accuracy of this method. Materials and Methods: A Calypso QA phantom with three Beacons was imaged by both MV and kV beams at a series of gantry angles on a Trilogy (Varian Medical Systems, Palo Alto, California, USA) while Beacon positions were simultaneously tracked using a Calypso 4D localization system (Calypso Medical Technologies, Inc., Seattle, WA, USA). Beacons were automatically detected on kV and MV projection images using in-house software, their 3D positions were calculated from MV-MV, kV-kV, or MV-kV pairs with a 60° or larger gantry angle separation between each pair, and compared with Calypso results. A special QA procedure was developed to assess geometric accuracy of MV and kV imaging systems on the Trilogy, and geometric parameter deviations, particularly detector center offsets, were applied to correct the 3D position calculations. Results: A phantom was placed at known positions based on the detected Calypso Beacon centroids. Both MV and kV images were acquired at 12 gantry angles with an increment of 30°. 2D and 3D positions were calculated. The different calculation modalities resulted in noticeable discrepancies from the Calypso 3D positions. The application of a geometric correction is capable of reducing these deviations, with the measured net shifts matching calypso results within 0.1 mm. Conclusion: Geometric correction after QA of imaging geometry helps improve detection accuracy. Implanted fiducial markers can be detected by multiple projections of either MV or kV x-ray beams with an accuracy of approximately 1 mm.

Original languageEnglish (US)
Title of host publicationWorld Congress on Medical Physics and Biomedical Engineering
Subtitle of host publicationRadiation Oncology
PublisherSpringer Verlag
Pages740-743
Number of pages4
Edition1
ISBN (Print)9783642034725
DOIs
StatePublished - 2009
EventWorld Congress on Medical Physics and Biomedical Engineering: Radiation Oncology - Munich, Germany
Duration: Sep 7 2009Sep 12 2009

Publication series

NameIFMBE Proceedings
Number1
Volume25
ISSN (Print)1680-0737

Other

OtherWorld Congress on Medical Physics and Biomedical Engineering: Radiation Oncology
Country/TerritoryGermany
CityMunich
Period9/7/099/12/09

Keywords

  • Fiducial marker
  • Geometric QA
  • IGRT
  • KV imaging
  • MV imaging

ASJC Scopus subject areas

  • Bioengineering
  • Biomedical Engineering

Fingerprint

Dive into the research topics of 'Accuracy evaluation of using MV EPID and/or integrated kV imaging system to locate 3D positions of internal fiducial markers using a Calypso system'. Together they form a unique fingerprint.

Cite this