T1 - A study on characteristics of radial arteries through ultrasonic waves
AU - Lee, Yu Jung
AU - Lee, Jeon
AU - Kim, Jong Yeol
PY - 2008
Y1 - 2008
N2 - The study aims to measure and analyze the thickness and depth of blood vessel on the pulse diagnosis locations (CHON, KWAN, CHUCK) and the blood velocity through the use of ultrasonic waves (LOGIQ5PRO, GE Medical, U.S.) in order to understand the structural difference of pulse diagnosis locations. The subjects included 44 healthy men and women (22.28±2.62 age) considered normal in terms of Body Mass Index (BMI). The thickness and depth of the blood vessel and the blood velocity were measured three times on CHON, KWAN and CHUCK to obtain the average value. Results showed there is a statistically significant difference among the variables measured on CHON, KWAN and CHUCK. A difference according to gender was also observed. This explains why an oriental medical doctor can tell the difference in pulses depending on the location of CHON, KWAN and CHUCK. In addition, the difference in pressure between CHON and KWAN was higher than that in pressure between KWAN and CHUCK. The findings explain why oriental medical doctors take pulses by dividing CHON, KWAN and CHUCK in the short length of the three fingers. It can be used to develop a pulse diagnosis device enabling accurate measurement according to the characteristics of blood vessel structure based on where the pulse is taken. Furthermore, the results can be used as basic data for the development of a pulse diagnosis simulator.
AB - The study aims to measure and analyze the thickness and depth of blood vessel on the pulse diagnosis locations (CHON, KWAN, CHUCK) and the blood velocity through the use of ultrasonic waves (LOGIQ5PRO, GE Medical, U.S.) in order to understand the structural difference of pulse diagnosis locations. The subjects included 44 healthy men and women (22.28±2.62 age) considered normal in terms of Body Mass Index (BMI). The thickness and depth of the blood vessel and the blood velocity were measured three times on CHON, KWAN and CHUCK to obtain the average value. Results showed there is a statistically significant difference among the variables measured on CHON, KWAN and CHUCK. A difference according to gender was also observed. This explains why an oriental medical doctor can tell the difference in pulses depending on the location of CHON, KWAN and CHUCK. In addition, the difference in pressure between CHON and KWAN was higher than that in pressure between KWAN and CHUCK. The findings explain why oriental medical doctors take pulses by dividing CHON, KWAN and CHUCK in the short length of the three fingers. It can be used to develop a pulse diagnosis device enabling accurate measurement according to the characteristics of blood vessel structure based on where the pulse is taken. Furthermore, the results can be used as basic data for the development of a pulse diagnosis simulator.
UR - http://www.scopus.com/inward/record.url?scp=61849140793&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=61849140793&partnerID=8YFLogxK
U2 - 10.1109/iembs.2008.4649696
DO - 10.1109/iembs.2008.4649696
M3 - Conference contribution
C2 - 19163199
AN - SCOPUS:61849140793
SN - 9781424418152
T3 - Proceedings of the 30th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBS'08 - "Personalized Healthcare through Technology"
SP - 2453
EP - 2456
BT - Proceedings of the 30th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBS'08
PB - IEEE Computer Society
T2 - 30th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBS'08
Y2 - 20 August 2008 through 25 August 2008
ER -