TY - JOUR
T1 - A Novel Timesaving Method for Hepatobiliary Imaging for Suspected Acute Cholecystitis
AU - Carter, Shawn S.
AU - Ehsan, Syed Ramisa
AU - Duszak, Richard
AU - Lee, Daniel J.
AU - Esteves, Fabio P.
AU - Brandon, David C.
AU - Halkar, Raghuveer K.
N1 - Publisher Copyright:
© 2016 Elsevier Inc.
PY - 2017/1/1
Y1 - 2017/1/1
N2 - Objective To optimize resource utilization of cholescintigraphy for suspected acute cholecystitis with a time-saving method without a loss in diagnostic accuracy. Materials and Methods Institutional review board approval was obtained for this retrospective study. Hepatobiliary imaging data for 81 patients with suspected acute cholecystitis were recalled for modification into 2 summed static images, using only the first and last 5 minutes of the dynamic images, thereby eliminating the middle 50 minutes of imaging data. Two nuclear medicine physicians interpreted the summed images to assess visualization, and those interpretations were compared to the original reports based on using all 60 minutes of dynamic imaging. A third nuclear medicine physician mediated rare inter-reader interpretive disagreements. Comparison of interpretations of time-saving and conventional methods and also inter-observer variability was achieved using the Cohen κ coefficient analysis. Results Interpretations rendered using the time-saving method showed near-perfect agreement with those based on the full dynamic imaging protocol (Cohen κ coefficient = 0.92 for both readers). Furthermore, nuclear medicine physician readers agreed with each other (Cohen κ coefficient = 0.95 between the 2 readers), indicating minimal inter-observer variability using this novel optimized technique. Conclusion In the setting of suspected acute cholecystitis, imaging resource utilization may be improved, via reduced gamma camera and technologist time, using a novel time-saving method without sacrificing diagnostic accuracy. Multicenter larger trials, however, will be necessary to establish reproducibility.
AB - Objective To optimize resource utilization of cholescintigraphy for suspected acute cholecystitis with a time-saving method without a loss in diagnostic accuracy. Materials and Methods Institutional review board approval was obtained for this retrospective study. Hepatobiliary imaging data for 81 patients with suspected acute cholecystitis were recalled for modification into 2 summed static images, using only the first and last 5 minutes of the dynamic images, thereby eliminating the middle 50 minutes of imaging data. Two nuclear medicine physicians interpreted the summed images to assess visualization, and those interpretations were compared to the original reports based on using all 60 minutes of dynamic imaging. A third nuclear medicine physician mediated rare inter-reader interpretive disagreements. Comparison of interpretations of time-saving and conventional methods and also inter-observer variability was achieved using the Cohen κ coefficient analysis. Results Interpretations rendered using the time-saving method showed near-perfect agreement with those based on the full dynamic imaging protocol (Cohen κ coefficient = 0.92 for both readers). Furthermore, nuclear medicine physician readers agreed with each other (Cohen κ coefficient = 0.95 between the 2 readers), indicating minimal inter-observer variability using this novel optimized technique. Conclusion In the setting of suspected acute cholecystitis, imaging resource utilization may be improved, via reduced gamma camera and technologist time, using a novel time-saving method without sacrificing diagnostic accuracy. Multicenter larger trials, however, will be necessary to establish reproducibility.
UR - http://www.scopus.com/inward/record.url?scp=84971602029&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84971602029&partnerID=8YFLogxK
U2 - 10.1067/j.cpradiol.2016.04.005
DO - 10.1067/j.cpradiol.2016.04.005
M3 - Article
C2 - 27268320
AN - SCOPUS:84971602029
SN - 0363-0188
VL - 46
SP - 6
EP - 9
JO - Current Problems in Diagnostic Radiology
JF - Current Problems in Diagnostic Radiology
IS - 1
ER -