Utilization and Outcomes of Children Treated with Direct Thrombin Inhibitors on Paracorporeal Ventricular Assist Device Support

Christina J. Vanderpluym, Ryan S. Cantor, Desiree MacHado, Gerald Boyle, Lindsay May, Eric Griffiths, Robert A. Niebler, Angela Lorts, Joseph Rossano, David L. Sutcliffe, Irene D. Lytrivi, Holger Buchholz, Francis Fynn-Thompson, Beth Hawkins, Jennifer Conway

Research output: Contribution to journalArticlepeer-review

56 Scopus citations

Abstract

Thrombotic and bleeding complications have historically been major causes of morbidity and mortality in pediatric ventricular assist device (VAD) support. Standard anticoagulation with unfractionated heparin is fraught with problems related to its heterogeneous biochemical composition and unpredictable pharmacokinetics. We sought to describe the utilization and outcomes in children with paracorporeal VAD support who are treated with direct thrombin inhibitors (DTIs) antithrombosis therapy. Retrospective multicenter review of all pediatric patients (aged <19 years) treated with a DTI (bivalirudin or argatroban) on paracorporeal VAD support, examining bleeding and thrombotic adverse events. From May 2012 to 2018, 43 children (21 females) at 10 centers in North America, median age 9.5 months (0.1-215 months) weighing 8.6 kg (2.8-150 kg), were implanted with paracorporeal VADs and treated with a DTI. Diagnoses included cardiomyopathy 40% (n = 17), congenital heart disease 37% (n = 16; single ventricle n = 5), graft vasculopathy 9% (n = 4), and other 14% (n = 6). First device implanted included Berlin Heart EXCOR 49% (n = 21), paracorporeal continuous flow device 44% (n = 19), and combination of devices in 7% (n = 3). Adverse events on DTI therapy included; major bleeding in 16% (n = 7) (2.6 events per 1,000 patient days of support on DTI), and stroke 12% (n = 5) (1.7 events per 1,000 patient days of support on DTI). Overall survival to transplantation (n = 30) or explantation (n = 8) was 88%. This is the largest multicenter experience of DTI use for anticoagulation therapy in pediatric VAD support. Outcomes are encouraging with lower major bleeding and stroke event rate than that reported in literature using other anticoagulation agents in pediatric VAD support.

Original languageEnglish (US)
Pages (from-to)939-945
Number of pages7
JournalASAIO Journal
Volume66
Issue number8
DOIs
StatePublished - Aug 1 2020

ASJC Scopus subject areas

  • Biophysics
  • Bioengineering
  • Biomaterials
  • Biomedical Engineering

Fingerprint

Dive into the research topics of 'Utilization and Outcomes of Children Treated with Direct Thrombin Inhibitors on Paracorporeal Ventricular Assist Device Support'. Together they form a unique fingerprint.

Cite this