TY - JOUR
T1 - Treatment of type II endoleak using Onyx with long-term imaging follow-up
AU - Khaja, Minhaj S.
AU - Park, Auh Whan
AU - Swee, Warren
AU - Evans, Avery J.
AU - Fritz Angle, J.
AU - Turba, Ulku C.
AU - Sabri, Saher S.
AU - Matsumoto, Alan H.
PY - 2014/6
Y1 - 2014/6
N2 - Purpose: The purpose of our study is to report our experience with the use of an ethylene vinyl alcohol copolymer (Onyx) in an off-label fashion for the treatment of type II endoleak after endovascular repair of the thoracic (TEVAR) and abdominal (EVAR) aorta. Methods: A retrospective review of patients with type I and/or II endoleak treated with Onyx was performed. Data regarding the technical, clinical, and imaging outcomes were collected. Technical success was defined as decreased or eliminated endoleak on the first imaging follow-up. Clinical success was defined as unchanged or decreased aneurysm sac size on subsequent follow-up. Results: Eighteen patients (15 male, 3 female) with a mean age of 79 years (range 69-92) met inclusion criteria (16 abdominal aortic aneurysm, 2 thoracic aortic aneurysm). Sixteen patients had type II endoleak, and 2 had complex type II endoleak with a type I component. The interval between endograft placement and treatment was a mean of 30 months. Direct sac treatment approach was used in 13 patients; transarterial approach was used in 3 patients. Seven patients required the use of coils, N-butyl cyanoacrylate glue, or Amplatzer vascular plugs. The average volume of Onyx used per treatment was 5.6 mL (range 2.5-13). Duration of imaging follow-up was 0.75-72.5 months (mean 32.8). Sixteen of 18 (88.9 %) patients had initial technical and clinical success. Two of 18 patients (11.1 %) were initial technical failures, and 1 remained a failure despite a second treatment and attempted surgical ligation. Eight of 18 (44.4 %) of patients eventually required a second intervention, 5 (27.8 %) of them due to delayed clinical failure. Complications included 1 psoas hematoma, 1 transient L2 nerve paresis, and 1 intraperitoneal Onyx leak; all of these were without clinical sequelae. Conclusion: Onyx with or without coil/glue/Amplatzer plug embolization is safe and useful in the treatment of type II endoleak after TEVAR and EVAR. However, long-term clinical and imaging follow-up is needed for early detection and management of recurrence of the primary endoleak or the development of new, secondary endoleaks or enlargement of the aneurysm sac.
AB - Purpose: The purpose of our study is to report our experience with the use of an ethylene vinyl alcohol copolymer (Onyx) in an off-label fashion for the treatment of type II endoleak after endovascular repair of the thoracic (TEVAR) and abdominal (EVAR) aorta. Methods: A retrospective review of patients with type I and/or II endoleak treated with Onyx was performed. Data regarding the technical, clinical, and imaging outcomes were collected. Technical success was defined as decreased or eliminated endoleak on the first imaging follow-up. Clinical success was defined as unchanged or decreased aneurysm sac size on subsequent follow-up. Results: Eighteen patients (15 male, 3 female) with a mean age of 79 years (range 69-92) met inclusion criteria (16 abdominal aortic aneurysm, 2 thoracic aortic aneurysm). Sixteen patients had type II endoleak, and 2 had complex type II endoleak with a type I component. The interval between endograft placement and treatment was a mean of 30 months. Direct sac treatment approach was used in 13 patients; transarterial approach was used in 3 patients. Seven patients required the use of coils, N-butyl cyanoacrylate glue, or Amplatzer vascular plugs. The average volume of Onyx used per treatment was 5.6 mL (range 2.5-13). Duration of imaging follow-up was 0.75-72.5 months (mean 32.8). Sixteen of 18 (88.9 %) patients had initial technical and clinical success. Two of 18 patients (11.1 %) were initial technical failures, and 1 remained a failure despite a second treatment and attempted surgical ligation. Eight of 18 (44.4 %) of patients eventually required a second intervention, 5 (27.8 %) of them due to delayed clinical failure. Complications included 1 psoas hematoma, 1 transient L2 nerve paresis, and 1 intraperitoneal Onyx leak; all of these were without clinical sequelae. Conclusion: Onyx with or without coil/glue/Amplatzer plug embolization is safe and useful in the treatment of type II endoleak after TEVAR and EVAR. However, long-term clinical and imaging follow-up is needed for early detection and management of recurrence of the primary endoleak or the development of new, secondary endoleaks or enlargement of the aneurysm sac.
UR - http://www.scopus.com/inward/record.url?scp=84901670687&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84901670687&partnerID=8YFLogxK
U2 - 10.1007/s00270-013-0706-z
DO - 10.1007/s00270-013-0706-z
M3 - Article
C2 - 23903786
AN - SCOPUS:84901670687
SN - 7415-5101
VL - 37
SP - 613
EP - 622
JO - Cardiovascular Radiology
JF - Cardiovascular Radiology
IS - 3
ER -