TY - JOUR
T1 - The effect of obesity on bioimpedance cardiac index
AU - Brown, Carlos V R
AU - Martin, Matthew J.
AU - Shoemaker, William C.
AU - Wo, Charles C J
AU - Chan, Linda
AU - Azarow, Kenneth
AU - Demetriades, Demetrios
AU - Luber, John
PY - 2005/5
Y1 - 2005/5
N2 - Background: Cardiac performance may be assessed noninvasively at the patient's bedside by using thoracic bioimpedance. However, it is unclear if this technique can be used reliably in critically injured obese patients because of increased body habitus and chest wall mass. Methods: A prospectively maintained database was used to identify all trauma patients admitted to the intensive care unit who underwent simultaneous measurement of cardiac performance by using both thoracic bioimpedance and thermodilution. Patients were divided into 2 groups based on their body mass index (BMI). Patients with a BMI less than 30 kg/m2 were classified as nonobese, and patients with a BMI of 30 kg/m2 or greater were categorized as obese. Results: There were 285 patients who underwent 1,138 simultaneous measurements of cardiac index by using both bioimpedance and thermodilution. There were 211 nonobese patients (BMI = 25 ± 3 kg/m2) and 74 obese patients (BMI = 34 ± 4 kg/m2). Bioimpedance correlated well with thermodilution for the entire population (r = .84, P < .0001), and was reliable equally in obese (r = .85, P < .0001) and nonobese (r = .82, P < .0001) patients. There actually was less test bias in the obese group (-.06 ± .69) than in the nonobese group (-.16 ± .75, P = .04). Conclusions: Thoracic bioimpedance technology may be used reliably as a noninvasive alternative to pulmonary artery catheterization for assessment of cardiac performance in critically injured obese patients.
AB - Background: Cardiac performance may be assessed noninvasively at the patient's bedside by using thoracic bioimpedance. However, it is unclear if this technique can be used reliably in critically injured obese patients because of increased body habitus and chest wall mass. Methods: A prospectively maintained database was used to identify all trauma patients admitted to the intensive care unit who underwent simultaneous measurement of cardiac performance by using both thoracic bioimpedance and thermodilution. Patients were divided into 2 groups based on their body mass index (BMI). Patients with a BMI less than 30 kg/m2 were classified as nonobese, and patients with a BMI of 30 kg/m2 or greater were categorized as obese. Results: There were 285 patients who underwent 1,138 simultaneous measurements of cardiac index by using both bioimpedance and thermodilution. There were 211 nonobese patients (BMI = 25 ± 3 kg/m2) and 74 obese patients (BMI = 34 ± 4 kg/m2). Bioimpedance correlated well with thermodilution for the entire population (r = .84, P < .0001), and was reliable equally in obese (r = .85, P < .0001) and nonobese (r = .82, P < .0001) patients. There actually was less test bias in the obese group (-.06 ± .69) than in the nonobese group (-.16 ± .75, P = .04). Conclusions: Thoracic bioimpedance technology may be used reliably as a noninvasive alternative to pulmonary artery catheterization for assessment of cardiac performance in critically injured obese patients.
KW - Cardiac output
KW - Noninvasive monitoring
KW - Obesity
KW - Thermodilution
KW - Thoracic bioimpedance
UR - http://www.scopus.com/inward/record.url?scp=18044389302&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=18044389302&partnerID=8YFLogxK
U2 - 10.1016/j.amjsurg.2005.01.030
DO - 10.1016/j.amjsurg.2005.01.030
M3 - Article
C2 - 15862494
AN - SCOPUS:18044389302
SN - 0002-9610
VL - 189
SP - 547
EP - 551
JO - American Journal of Surgery
JF - American Journal of Surgery
IS - 5 SPEC. ISS.
ER -