TY - JOUR
T1 - SU‐GG‐T‐331
T2 - Performance Evaluation of a New‐Model P‐Type Si Diode for Small Field Dosimetry
AU - Dugas, J.
AU - Speiser, M.
AU - Medin, P.
AU - Solberg, T.
PY - 2010
Y1 - 2010
N2 - Purpose: Accurate small field characterization affects patient safety and success in stereotactic radiosurgery (SRS). This study provides critical characterization data for clinical implementation of a new p‐type Si scanning diode, the Exradin SD1, for SRS dosimetry. Method and Materials: SD1 performance was compared against the Scanditronix‐Wellhöfer SFD stereotactic diode and PTW PinPoint® ionization chamber for a 6 MV beam. Percent depth dose (PDD) curves for square, jaw‐shaped fields (12, 24, 40, 80, and 98 mm) and diagonal profiles at 5, 14, 25, 50, 100, 200, and 350‐mm depths (98×98‐mm2 field) were attained in a large water phantom. Scatter factors were calculated from output measurements in a 30×30×30‐cm3 water tank at 100‐cm SSD, 5‐cm depth for MLC‐shaped square field sizes of 6, 12, 18, 24, 36, 42, 60, and 80 mm (98×98‐mm2 reference field). Results: SD1 PDD data agrees well with SFD diode and pinpoint chamber data at depths ≥dmix for all measured fields. The SD1 overestimates dose in the buildup region, likely because its design includes a 3.5 mm dome of buildup material over the active detector. Displacement of the effective measurement point from the SFD diode surface is 0.7 mm. Both SD1 and SFD diodes over‐estimate PDD for fields ≥40 mm, likely from silicon's increased sensitivity to low‐energy scatter. All three dosimeters produced similar beam profiles at all depths, excepting minor disagreement in the tail regions. The SD1 diode exhibited no drift (change in response over time), possibly due to higher outputs yielding smaller percentage drift. SD1‐measured scatter factors trend higher than their ion chamber‐measured counterparts with poor agreement for the smallest (6mm) field size evidenced by large absolute differences in measured values between all three dosimeters. Conclusion: Exradin SD1 performance for small field measurements has been evaluated, providing critical characterization data for its clinical implementation for SRS dosimetry.
AB - Purpose: Accurate small field characterization affects patient safety and success in stereotactic radiosurgery (SRS). This study provides critical characterization data for clinical implementation of a new p‐type Si scanning diode, the Exradin SD1, for SRS dosimetry. Method and Materials: SD1 performance was compared against the Scanditronix‐Wellhöfer SFD stereotactic diode and PTW PinPoint® ionization chamber for a 6 MV beam. Percent depth dose (PDD) curves for square, jaw‐shaped fields (12, 24, 40, 80, and 98 mm) and diagonal profiles at 5, 14, 25, 50, 100, 200, and 350‐mm depths (98×98‐mm2 field) were attained in a large water phantom. Scatter factors were calculated from output measurements in a 30×30×30‐cm3 water tank at 100‐cm SSD, 5‐cm depth for MLC‐shaped square field sizes of 6, 12, 18, 24, 36, 42, 60, and 80 mm (98×98‐mm2 reference field). Results: SD1 PDD data agrees well with SFD diode and pinpoint chamber data at depths ≥dmix for all measured fields. The SD1 overestimates dose in the buildup region, likely because its design includes a 3.5 mm dome of buildup material over the active detector. Displacement of the effective measurement point from the SFD diode surface is 0.7 mm. Both SD1 and SFD diodes over‐estimate PDD for fields ≥40 mm, likely from silicon's increased sensitivity to low‐energy scatter. All three dosimeters produced similar beam profiles at all depths, excepting minor disagreement in the tail regions. The SD1 diode exhibited no drift (change in response over time), possibly due to higher outputs yielding smaller percentage drift. SD1‐measured scatter factors trend higher than their ion chamber‐measured counterparts with poor agreement for the smallest (6mm) field size evidenced by large absolute differences in measured values between all three dosimeters. Conclusion: Exradin SD1 performance for small field measurements has been evaluated, providing critical characterization data for its clinical implementation for SRS dosimetry.
UR - http://www.scopus.com/inward/record.url?scp=85024794039&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85024794039&partnerID=8YFLogxK
U2 - 10.1118/1.3468728
DO - 10.1118/1.3468728
M3 - Article
AN - SCOPUS:85024794039
SN - 0094-2405
VL - 37
SP - 3262
JO - Medical Physics
JF - Medical Physics
IS - 6
ER -