TY - JOUR
T1 - Real-time MRI motion estimation through an unsupervised k-space-driven deformable registration network (KS-RegNet)
AU - Shao, Hua Chieh
AU - Li, Tian
AU - Dohopolski, Michael J.
AU - Wang, Jing
AU - Cai, Jing
AU - Tan, Jun
AU - Wang, Kai
AU - Zhang, You
N1 - Publisher Copyright:
© 2022 Institute of Physics and Engineering in Medicine.
PY - 2022/7/7
Y1 - 2022/7/7
N2 - Purpose. Real-time three-dimensional (3D) magnetic resonance (MR) imaging is challenging because of slow MR signal acquisition, leading to highly under-sampled k-space data. Here, we proposed a deep learning-based, k-space-driven deformable registration network (KS-RegNet) for real-time 3D MR imaging. By incorporating prior information, KS-RegNet performs a deformable image registration between a fully-sampled prior image and on-board images acquired from highly-under-sampled k-space data, to generate high-quality on-board images for real-time motion tracking. Methods. KS-RegNet is an end-to-end, unsupervised network consisting of an input data generation block, a subsequent U-Net core block, and following operations to compute data fidelity and regularization losses. The input data involved a fully-sampled, complex-valued prior image, and the k-space data of an on-board, real-time MR image (MRI). From the k-space data, under-sampled real-time MRI was reconstructed by the data generation block to input into the U-Net core. In addition, to train the U-Net core to learn the under-sampling artifacts, the k-space data of the prior image was intentionally under-sampled using the same readout trajectory as the real-time MRI, and reconstructed to serve an additional input. The U-Net core predicted a deformation vector field that deforms the prior MRI to on-board real-time MRI. To avoid adverse effects of quantifying image similarity on the artifacts-ridden images, the data fidelity loss of deformation was evaluated directly in k-space. Results. Compared with Elastix and other deep learning network architectures, KS-RegNet demonstrated better and more stable performance. The average (±s.d.) DICE coefficients of KS-RegNet on a cardiac dataset for the 5-, 9-, and 13-spoke k-space acquisitions were 0.884 ± 0.025, 0.889 ± 0.024, and 0.894 ± 0.022, respectively; and the corresponding average (±s.d.) center-of-mass errors (COMEs) were 1.21 ± 1.09, 1.29 ± 1.22, and 1.01 ± 0.86 mm, respectively. KS-RegNet also provided the best performance on an abdominal dataset. Conclusion. KS-RegNet allows real-time MRI generation with sub-second latency. It enables potential real-time MR-guided soft tissue tracking, tumor localization, and radiotherapy plan adaptation.
AB - Purpose. Real-time three-dimensional (3D) magnetic resonance (MR) imaging is challenging because of slow MR signal acquisition, leading to highly under-sampled k-space data. Here, we proposed a deep learning-based, k-space-driven deformable registration network (KS-RegNet) for real-time 3D MR imaging. By incorporating prior information, KS-RegNet performs a deformable image registration between a fully-sampled prior image and on-board images acquired from highly-under-sampled k-space data, to generate high-quality on-board images for real-time motion tracking. Methods. KS-RegNet is an end-to-end, unsupervised network consisting of an input data generation block, a subsequent U-Net core block, and following operations to compute data fidelity and regularization losses. The input data involved a fully-sampled, complex-valued prior image, and the k-space data of an on-board, real-time MR image (MRI). From the k-space data, under-sampled real-time MRI was reconstructed by the data generation block to input into the U-Net core. In addition, to train the U-Net core to learn the under-sampling artifacts, the k-space data of the prior image was intentionally under-sampled using the same readout trajectory as the real-time MRI, and reconstructed to serve an additional input. The U-Net core predicted a deformation vector field that deforms the prior MRI to on-board real-time MRI. To avoid adverse effects of quantifying image similarity on the artifacts-ridden images, the data fidelity loss of deformation was evaluated directly in k-space. Results. Compared with Elastix and other deep learning network architectures, KS-RegNet demonstrated better and more stable performance. The average (±s.d.) DICE coefficients of KS-RegNet on a cardiac dataset for the 5-, 9-, and 13-spoke k-space acquisitions were 0.884 ± 0.025, 0.889 ± 0.024, and 0.894 ± 0.022, respectively; and the corresponding average (±s.d.) center-of-mass errors (COMEs) were 1.21 ± 1.09, 1.29 ± 1.22, and 1.01 ± 0.86 mm, respectively. KS-RegNet also provided the best performance on an abdominal dataset. Conclusion. KS-RegNet allows real-time MRI generation with sub-second latency. It enables potential real-time MR-guided soft tissue tracking, tumor localization, and radiotherapy plan adaptation.
KW - MR-guided radiotherapy
KW - U-Net
KW - deep learning
KW - deformable image registration
KW - motion estimation
KW - real-time MRI
UR - http://www.scopus.com/inward/record.url?scp=85133629132&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85133629132&partnerID=8YFLogxK
U2 - 10.1088/1361-6560/ac762c
DO - 10.1088/1361-6560/ac762c
M3 - Article
C2 - 35667374
AN - SCOPUS:85133629132
SN - 0031-9155
VL - 67
JO - Physics in medicine and biology
JF - Physics in medicine and biology
IS - 13
M1 - 135012
ER -