TY - JOUR
T1 - Prelamellar dissection donor corneal thickness is associated with Descemet stripping automated endothelial keratoplasty operative complications in the cornea preservation time study
AU - on behalf of the Cornea Preservation Time Study Group
AU - Ross, Kevin W.
AU - Stoeger, Christopher G.
AU - Rosenwasser, George O.D.
AU - O'Brien, Robert C.
AU - Szczotka-Flynn, Loretta B.
AU - Ayala, Allison R.
AU - Maguire, Maureen G.
AU - Benetz, Beth Ann
AU - Dahl, Patricia
AU - Drury, Donna C.
AU - Dunn, Steven P.
AU - Farazdaghi, Sameera M.
AU - Hoover, Caroline K.
AU - Macsai, Marian S.
AU - Mian, Shahzad I.
AU - Nordlund, Michael L.
AU - Penta, Jeffrey G.
AU - Soper, Mark C.
AU - Terry, Mark A.
AU - Verdier, David D.
AU - Williams, Doyce V.
AU - Lass, Jonathan H.
N1 - Funding Information:
The comprehensive list of participating CPTS clinical sites, investigators, and coordinators; eye bank investigators; members of the Operations, Executive, Eye Bank Advisory, Data and Safety Monitoring Committee; Coordinating Center, Cornea Image Analysis Reading Center (CIARC), and Data Management and Analysis Center Staff; and the National Eye Institute staff have been previously published (Cornea. 2015;34:601–608; JAMA Ophthalmology. 2017:1401–09) The content is solely the responsibility of the authors and does not necessarily represent the official views of the National Eye Institute or the National Institutes of Health. Additional support was provided by Eye Bank Association of America, The Cornea Society, Vision Share, Inc., Alabama Eye Bank, Cleveland Eye Bank Foundation, Eversight, Eye-Bank for Sight Restoration, Iowa Lions Eye Bank, Lions Eye Bank of Albany, San Diego Eye Bank, and SightLife.
Funding Information:
Supported by cooperative agreements with the National Eye Institute, National Institutes of Health, and Department of Health and Human Services EY20797 and EY20798.
Publisher Copyright:
© 2019 Wolters Kluwer Health, Inc. All rights reserved.
PY - 2019/9
Y1 - 2019/9
N2 - Purpose: To identify donor and recipient factors, including eye bank tissue observations, predictive of operative complications in the Cornea Preservation Time Study. Methods: One thousand three hundred thirty study eyes undergoing Descemet stripping automated endothelial keratoplasty for Fuchs dystrophy or pseudophakic/aphakic corneal edema were randomized to receive a donor cornea with preservation time (PT) of 0 to 7 days (N = 675) or 8 to 14 days (N = 655). Donor factors included demographics, prelamellar corneal and postlamellar lenticule dissection thickness, central endothelial cell density, and tissue processing time. Recipient factors included demographics, intraocular pressure, and glaucoma medications or surgery (trabeculectomy, laser trabeculoplasty). Eye bank observations included donor tissue folds, pleomorphism/polymegethism, and endothelial cell abnormalities. Possible tissue-related operative complications were recorded including difficult donor lenticule unfolding and positioning. Multivariable logistic regression with backward selection was used to identify statistically significant (P, 0.01) associations between factors and operative complications. Results: The only factor predictive of operative complications [58 (4.4%) of 1330 surgeries] was prelamellar dissection donor corneal thickness (P = 0.002). For every 50 mm of donor corneal thickness prior to lamellar dissection, operative complication odds increased by 40% (odds ratio [99% confidence interval (CI)]: 1.40 [1.06-1.83]) adjusting for PT and whether the epithelium was on or off. The estimated mean prelamellar dissection donor corneal thickness for PT 0 to 7 days was 537 mm (99% CI: 516 mm-558 mm) compared with 567 mm (99% CI: 546 mm-588 mm) for PT 8 to 14 days (P, 0.001). Conclusions: Thicker donor tissue (prelamellar dissection) is associated with operative complications and should be considered in tissue selection for Descemet stripping automated endothelial keratoplasty lenticule preparation.
AB - Purpose: To identify donor and recipient factors, including eye bank tissue observations, predictive of operative complications in the Cornea Preservation Time Study. Methods: One thousand three hundred thirty study eyes undergoing Descemet stripping automated endothelial keratoplasty for Fuchs dystrophy or pseudophakic/aphakic corneal edema were randomized to receive a donor cornea with preservation time (PT) of 0 to 7 days (N = 675) or 8 to 14 days (N = 655). Donor factors included demographics, prelamellar corneal and postlamellar lenticule dissection thickness, central endothelial cell density, and tissue processing time. Recipient factors included demographics, intraocular pressure, and glaucoma medications or surgery (trabeculectomy, laser trabeculoplasty). Eye bank observations included donor tissue folds, pleomorphism/polymegethism, and endothelial cell abnormalities. Possible tissue-related operative complications were recorded including difficult donor lenticule unfolding and positioning. Multivariable logistic regression with backward selection was used to identify statistically significant (P, 0.01) associations between factors and operative complications. Results: The only factor predictive of operative complications [58 (4.4%) of 1330 surgeries] was prelamellar dissection donor corneal thickness (P = 0.002). For every 50 mm of donor corneal thickness prior to lamellar dissection, operative complication odds increased by 40% (odds ratio [99% confidence interval (CI)]: 1.40 [1.06-1.83]) adjusting for PT and whether the epithelium was on or off. The estimated mean prelamellar dissection donor corneal thickness for PT 0 to 7 days was 537 mm (99% CI: 516 mm-558 mm) compared with 567 mm (99% CI: 546 mm-588 mm) for PT 8 to 14 days (P, 0.001). Conclusions: Thicker donor tissue (prelamellar dissection) is associated with operative complications and should be considered in tissue selection for Descemet stripping automated endothelial keratoplasty lenticule preparation.
KW - Corneal endothelium
KW - Descemet stripping automated endothelial keratoplasty
KW - Eye banking
UR - http://www.scopus.com/inward/record.url?scp=85071349786&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85071349786&partnerID=8YFLogxK
U2 - 10.1097/ICO.0000000000002040
DO - 10.1097/ICO.0000000000002040
M3 - Article
C2 - 31180926
AN - SCOPUS:85071349786
SN - 0277-3740
VL - 38
SP - 1069
EP - 1076
JO - Cornea
JF - Cornea
IS - 9