TY - JOUR
T1 - Perioperative outcomes, transfusion requirements, and inflammatory response after coronary artery bypass grafting with off-pump, mini-extracorporeal, and on-pump circulation techniques
AU - Brinkman, William T.
AU - Squiers, John J.
AU - Filardo, Giovanni
AU - Arsalan, Mani
AU - Smith, Robert L.
AU - Moore, David
AU - Mack, Michael J.
AU - Dimaio, J. Michael
PY - 2015/12/1
Y1 - 2015/12/1
N2 - Objectives Mini-extracorporeal circulation (MECC) units were developed to reduce postoperative morbidity, transfusion requirements, and inflammation associated with conventional on-pump coronary artery bypass (ONCAB) surgery without the technical demands of the off-pump (OPCAB) technique. We compared perioperative outcomes and inflammatory mediation among OPCAB, MECC, and ONCAB techniques. Methods We prospectively enrolled 102 patients undergoing elective isolated coronary bypass grafting. Perfusion methods were OPCAB (n = 34), MECC (n = 34), and ONCAB (n = 34). Serial blood samples were collected to measure serum inflammatory markers. Results There were no operative deaths or strokes. Total red blood cell (RBC) products used in OPCAB, MECC, and ONCAB patients were 0.676, 1.000, and 1.235 units, respectively. Adjusted (by splined Society of Thoracic Surgeons operative risk score) analysis showed no statistically significant differences in mean RBC product use among the different operative systems (OPCAB vs MECC, P = 0.580; OPCAB vs ONCAB, P = 0.311; MECC vs ONCAB, P = 0.633). Adjusted (by Society of Thoracic Surgeons risk score and baseline level) mean plasma level differences (24 hours postoperative - baseline) of C-reactive protein for OPCAB (117.89; 95% confidence interval [95% CI], 106.23-129.54) and for MECC (124.88; 95% CI, 113.45-136.32) were significantly higher than for ONCAB (98.82; 95% CI, 86.40-111.24). No significant adjusted differences (P = 0.304) in interleukin-6 level changes were observed. Conclusions Off-pump coronary artery bypass and MECC did not significantly reduce mean total RBC transfusion requirements. Off-pump coronary artery bypass and MECC were associated with greater C-reactive protein elevation than ONCAB, suggestive of an increased inflammatory response to each of these techniques.
AB - Objectives Mini-extracorporeal circulation (MECC) units were developed to reduce postoperative morbidity, transfusion requirements, and inflammation associated with conventional on-pump coronary artery bypass (ONCAB) surgery without the technical demands of the off-pump (OPCAB) technique. We compared perioperative outcomes and inflammatory mediation among OPCAB, MECC, and ONCAB techniques. Methods We prospectively enrolled 102 patients undergoing elective isolated coronary bypass grafting. Perfusion methods were OPCAB (n = 34), MECC (n = 34), and ONCAB (n = 34). Serial blood samples were collected to measure serum inflammatory markers. Results There were no operative deaths or strokes. Total red blood cell (RBC) products used in OPCAB, MECC, and ONCAB patients were 0.676, 1.000, and 1.235 units, respectively. Adjusted (by splined Society of Thoracic Surgeons operative risk score) analysis showed no statistically significant differences in mean RBC product use among the different operative systems (OPCAB vs MECC, P = 0.580; OPCAB vs ONCAB, P = 0.311; MECC vs ONCAB, P = 0.633). Adjusted (by Society of Thoracic Surgeons risk score and baseline level) mean plasma level differences (24 hours postoperative - baseline) of C-reactive protein for OPCAB (117.89; 95% confidence interval [95% CI], 106.23-129.54) and for MECC (124.88; 95% CI, 113.45-136.32) were significantly higher than for ONCAB (98.82; 95% CI, 86.40-111.24). No significant adjusted differences (P = 0.304) in interleukin-6 level changes were observed. Conclusions Off-pump coronary artery bypass and MECC did not significantly reduce mean total RBC transfusion requirements. Off-pump coronary artery bypass and MECC were associated with greater C-reactive protein elevation than ONCAB, suggestive of an increased inflammatory response to each of these techniques.
KW - conventional cardiopulmonary bypass
KW - coronary artery bypass grafting
KW - mini-extracorporeal circulation
KW - off-pump coronary artery bypass
UR - http://www.scopus.com/inward/record.url?scp=84948955362&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84948955362&partnerID=8YFLogxK
U2 - 10.1097/JIM.0000000000000240
DO - 10.1097/JIM.0000000000000240
M3 - Article
C2 - 26448506
AN - SCOPUS:84948955362
SN - 1081-5589
VL - 63
SP - 916
EP - 920
JO - Journal of Investigative Medicine
JF - Journal of Investigative Medicine
IS - 8
ER -