TY - JOUR
T1 - Mathematical Modeling of Arterial Blood Pressure Using Photo- Plethysmography Signal in Breath-hold Maneuver
AU - Zadi, Armin Soltan
AU - Alex, Raichel M.
AU - Zhang, Rong
AU - Watenpaugh, Donald E.
AU - Behbehani, Khosrow
PY - 2018/7/1
Y1 - 2018/7/1
N2 - recent research has shown that each apnea episode results in a significant rise of the beat-to-beat blood pressure followed by a drop to the pre-episode levels when patient resumes normal breathing. While the physiological implications of these repetitive and significant oscillations are still unknown, it is of interest to quantify them. Since current array of instruments deployed for polysomnography studies does not include beat-to-beat measurement of blood pressure, but includes oximetry which can supply pulsatile photoplethysmography (PPG) signal, in addition to percent oxygen saturation. Hence, we have investigated a new method for continuous estimation of systolic (SBP), diastolic (DBP), and mean (MBP) blood pressure waveforms from PPG. Peaks and troughs of PPG waveform are used as input to a 5th order autoregressive moving average model to construct estimates of SBP, DBP, and MBP waveforms. Since breath hold maneuvers are shown to faithfully simulate apnea episodes, we evaluated the performance of the proposed method in 7 subjects (4 F; $32 \pm 4$ yrs., BMI $24.57 \pm 3.87$ kg/m2) in supine position doing 5 breath holding maneuvers with 90s of normal breathing between them. The modeling error ranges were (all units are in mmHg $) 0.88 \pm 4.87$ to $- 2.19 \pm 5.73($ SBP); $0.29 \pm 2.39$ to $- 0.97 \pm 3.83($ DBP); and $- 0.42 \pm 2.64$ to $- 1.17 \pm 3.82($ MBP). The cross validation error ranges were $0.28 \pm 6.45$ to $- 1.74 \pm 6.55($ SBP); $0.09 \pm 3.37$ to $0.97 \pm 3.67($ DBP); and $0.33 \pm 4.34$ to $- 0.87 \pm 4.42($ MBP). The overall level of estimation error, as measured by the root mean squared of the model residuals, was less than 7 mmHg.
AB - recent research has shown that each apnea episode results in a significant rise of the beat-to-beat blood pressure followed by a drop to the pre-episode levels when patient resumes normal breathing. While the physiological implications of these repetitive and significant oscillations are still unknown, it is of interest to quantify them. Since current array of instruments deployed for polysomnography studies does not include beat-to-beat measurement of blood pressure, but includes oximetry which can supply pulsatile photoplethysmography (PPG) signal, in addition to percent oxygen saturation. Hence, we have investigated a new method for continuous estimation of systolic (SBP), diastolic (DBP), and mean (MBP) blood pressure waveforms from PPG. Peaks and troughs of PPG waveform are used as input to a 5th order autoregressive moving average model to construct estimates of SBP, DBP, and MBP waveforms. Since breath hold maneuvers are shown to faithfully simulate apnea episodes, we evaluated the performance of the proposed method in 7 subjects (4 F; $32 \pm 4$ yrs., BMI $24.57 \pm 3.87$ kg/m2) in supine position doing 5 breath holding maneuvers with 90s of normal breathing between them. The modeling error ranges were (all units are in mmHg $) 0.88 \pm 4.87$ to $- 2.19 \pm 5.73($ SBP); $0.29 \pm 2.39$ to $- 0.97 \pm 3.83($ DBP); and $- 0.42 \pm 2.64$ to $- 1.17 \pm 3.82($ MBP). The cross validation error ranges were $0.28 \pm 6.45$ to $- 1.74 \pm 6.55($ SBP); $0.09 \pm 3.37$ to $0.97 \pm 3.67($ DBP); and $0.33 \pm 4.34$ to $- 0.87 \pm 4.42($ MBP). The overall level of estimation error, as measured by the root mean squared of the model residuals, was less than 7 mmHg.
UR - http://www.scopus.com/inward/record.url?scp=85056594803&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85056594803&partnerID=8YFLogxK
U2 - 10.1109/EMBC.2018.8512776
DO - 10.1109/EMBC.2018.8512776
M3 - Article
C2 - 30440963
AN - SCOPUS:85056594803
SN - 1557-170X
VL - 2018
SP - 2711
EP - 2714
JO - Conference proceedings : ... Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Conference
JF - Conference proceedings : ... Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Conference
ER -