TY - JOUR
T1 - Laboratory testing of femoral venous cannulae
T2 - Effect of size, position and negative pressure on flow
AU - Kurusz, Mark
AU - Deyo, Donald J.
AU - Sholar, Alina D.
AU - Tao, Weike
AU - Zwischenberger, Joseph B.
PY - 1999
Y1 - 1999
N2 - Femoral venous cannulae (17-28 French) were tested to compare flows obtained by their placement in a simulated inferior vena cava (IVC) or right atrium (RA) and by varying drainage pressures using gravity siphon drainage or a centrifugal pump in the venous line. The circuit consisted of conventional tubing and equipment including a segment of thin-walled latex tubing to simulate the IVC connected to a flexible reservoir to simulate the RA. The test fluid was a 40% glycerin solution. Flow was measured at height differentials of 30-60 cm (cannula-to-inlet of hard-shell venous reservoir) and with a -10 to -80 mmHg negative pressure created by the centrifugal pump. A roller pump returned the test fluid to a flexible bag to maintain a filling pressure of 0-1 mmHg. Flow increased modestly with an increasing height differential. When negative pressure was applied with the centrifugal pump, flow increased 10% and 18% (IVC and RA positions, respectively) compared to gravity siphon drainage conditions. There also was a tendency for flow to plateau or cease when the centrifugal pump was used at higher levels of negative pressure or when larger cannulae were used. We conclude: (1) position of smaller cannulae in the RA yield better flows than when the cannulae are larger and placed in the IVC; (2) smaller-sized cannulae are capable of achieving higher flows when the centrifugal pump is used; (3) cannulae must be properly positioned to achieve maximum flow, (4) the centrifugal pump will augment flow, but should be regulated to avoid extreme negative pressures; and (5) cannula design has no demonstrable effect on flow.
AB - Femoral venous cannulae (17-28 French) were tested to compare flows obtained by their placement in a simulated inferior vena cava (IVC) or right atrium (RA) and by varying drainage pressures using gravity siphon drainage or a centrifugal pump in the venous line. The circuit consisted of conventional tubing and equipment including a segment of thin-walled latex tubing to simulate the IVC connected to a flexible reservoir to simulate the RA. The test fluid was a 40% glycerin solution. Flow was measured at height differentials of 30-60 cm (cannula-to-inlet of hard-shell venous reservoir) and with a -10 to -80 mmHg negative pressure created by the centrifugal pump. A roller pump returned the test fluid to a flexible bag to maintain a filling pressure of 0-1 mmHg. Flow increased modestly with an increasing height differential. When negative pressure was applied with the centrifugal pump, flow increased 10% and 18% (IVC and RA positions, respectively) compared to gravity siphon drainage conditions. There also was a tendency for flow to plateau or cease when the centrifugal pump was used at higher levels of negative pressure or when larger cannulae were used. We conclude: (1) position of smaller cannulae in the RA yield better flows than when the cannulae are larger and placed in the IVC; (2) smaller-sized cannulae are capable of achieving higher flows when the centrifugal pump is used; (3) cannulae must be properly positioned to achieve maximum flow, (4) the centrifugal pump will augment flow, but should be regulated to avoid extreme negative pressures; and (5) cannula design has no demonstrable effect on flow.
UR - http://www.scopus.com/inward/record.url?scp=0032850024&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0032850024&partnerID=8YFLogxK
U2 - 10.1177/026765919901400510
DO - 10.1177/026765919901400510
M3 - Article
C2 - 10499655
AN - SCOPUS:0032850024
SN - 0267-6591
VL - 14
SP - 379
EP - 387
JO - Perfusion (United Kingdom)
JF - Perfusion (United Kingdom)
IS - 5
ER -