TY - JOUR
T1 - Intraobserver and interobserver reliability of two ultrasound measures of humeral head position in infants with neonatal brachial plexus palsy
AU - Vathana, Torpon
AU - Rust, Stace'
AU - Mills, Janith
AU - Wilkes, David
AU - Browne, Richard
AU - Carter, Peter R.
AU - Ezaki, Marybeth
N1 - Copyright:
Copyright 2017 Elsevier B.V., All rights reserved.
PY - 2007/8
Y1 - 2007/8
N2 - Background: Ultrasonographic evaluation of the hip in infants is considered both reliable and reproducible in the diagnosis of developmental dysplasia of the hip. Ultrasonographic evaluation of the shoulder in infants has been reported as a valuable diagnostic aid in dysplastic development following neonatal brachial plexus palsy. To our knowledge, there has been no study of the intraobserver reproducibility and interobserver reliability of sonography of the shoulder in infants with and without suspected posterior shoulder dislocation. Methods: Two identical but randomly ordered sets of the same deidentified sonographic images of shoulders in infants were given to radiologists, pediatric orthopaedists and orthopaedic residents, and fellows with varying degrees of experience in the evaluation of shoulder pathology in infants, who measured the position of the humeral head relative to the axis of the scapula. Intraobserver reproducibility and interobserver reliability of the measurements were assessed. Results: For the position of the humeral head with respect to the glenoid in both normal and abnormal conditions, the Pearson correlation coefficient for intraobserver reproducibility was 0.91 and the intraclass correlation coefficient for interobserver reliability was 0.875. For estimating the percentage of the humeral head posterior to the axis of the scapula, the Pearson correlation was 0.85 and the intraclass correlation coefficient was 0.77. Conclusions: Ultrasonographic examination of the shoulder in infants to assess for the position of the humeral head with respect to the scapula showed high intraobserver reproducibility and interobserver reliability. It is recommended as a reliable technique for evaluating shoulder position in infants with neonatal brachial plexus palsy.
AB - Background: Ultrasonographic evaluation of the hip in infants is considered both reliable and reproducible in the diagnosis of developmental dysplasia of the hip. Ultrasonographic evaluation of the shoulder in infants has been reported as a valuable diagnostic aid in dysplastic development following neonatal brachial plexus palsy. To our knowledge, there has been no study of the intraobserver reproducibility and interobserver reliability of sonography of the shoulder in infants with and without suspected posterior shoulder dislocation. Methods: Two identical but randomly ordered sets of the same deidentified sonographic images of shoulders in infants were given to radiologists, pediatric orthopaedists and orthopaedic residents, and fellows with varying degrees of experience in the evaluation of shoulder pathology in infants, who measured the position of the humeral head relative to the axis of the scapula. Intraobserver reproducibility and interobserver reliability of the measurements were assessed. Results: For the position of the humeral head with respect to the glenoid in both normal and abnormal conditions, the Pearson correlation coefficient for intraobserver reproducibility was 0.91 and the intraclass correlation coefficient for interobserver reliability was 0.875. For estimating the percentage of the humeral head posterior to the axis of the scapula, the Pearson correlation was 0.85 and the intraclass correlation coefficient was 0.77. Conclusions: Ultrasonographic examination of the shoulder in infants to assess for the position of the humeral head with respect to the scapula showed high intraobserver reproducibility and interobserver reliability. It is recommended as a reliable technique for evaluating shoulder position in infants with neonatal brachial plexus palsy.
UR - http://www.scopus.com/inward/record.url?scp=34547804407&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=34547804407&partnerID=8YFLogxK
U2 - 10.2106/JBJS.F.01263
DO - 10.2106/JBJS.F.01263
M3 - Article
C2 - 17671008
AN - SCOPUS:34547804407
SN - 0021-9355
VL - 89
SP - 1710
EP - 1715
JO - Journal of Bone and Joint Surgery - Series A
JF - Journal of Bone and Joint Surgery - Series A
IS - 8
ER -