TY - JOUR
T1 - Improved outcomes from extracorporeal membrane oxygenation versus ventricular assist device temporary support of primary graft dysfunction in heart transplant
AU - Takeda, Koji
AU - Li, Boyangzi
AU - Garan, Arthur R.
AU - Topkara, Veli K.
AU - Han, Jiho
AU - Colombo, Paolo C.
AU - Farr, Maryjane A.
AU - Naka, Yoshifumi
AU - Takayama, Hiroo
N1 - Publisher Copyright:
© 2017
PY - 2017/6
Y1 - 2017/6
N2 - Background Primary graft dysfunction (PGD) is one of the most common causes of early death after orthotopic heart transplantation. Mechanical circulatory support devices are required for severe forms of PGD. Venoarterial extracorporeal membrane oxygenation (VA-ECMO) and temporary ventricular assist device (VAD) support have both been reported to be useful for severe PGD. Methods Between January 2007 and December 2015, 597 patients received a heart transplant at our center. Of those, severe PGD developed in 44 patients (7.4%), and they received a continuous-flow external VAD (n = 17) or VA-ECMO (n = 27) support within 24 hours after transplant. We compared early and late outcomes between groups. Results Baseline characteristics were similar between groups. Implantation of the temporary VAD required longer cardiopulmonary bypass time compared with VA-ECMO (323 ± 86 minutes vs 216 ± 65 minutes, p < 0.0001). Patients who received a VAD were more likely to have longer support time (14 ± 17 days vs 5.2 ± 3.9 days, p = 0.011), a higher incidence of major bleeding requiring chest reexploration (77% vs 30%, p = 0.0047), and a higher incidence of renal failure requiring renal replacement therapy (53% vs 11%, p = 0.0045) after surgery. Overall hospital mortality was 27%. In-hospital mortality for VAD and VA-ECMO patients were 41% and 19%, respectively (p = 0.16). Ten patients (59%) were weaned from VAD support, and 24 (89%) were weaned from VA-ECMO support after adequate graft function recovery (p = 0.03). The 3-year post-transplant survival was 41% in the VAD group and 66% in the VA-ECMO group (p = 0.13). Conclusions For severe PGD, support with VA-ECMO appears to result in better clinical outcomes compared with VAD.
AB - Background Primary graft dysfunction (PGD) is one of the most common causes of early death after orthotopic heart transplantation. Mechanical circulatory support devices are required for severe forms of PGD. Venoarterial extracorporeal membrane oxygenation (VA-ECMO) and temporary ventricular assist device (VAD) support have both been reported to be useful for severe PGD. Methods Between January 2007 and December 2015, 597 patients received a heart transplant at our center. Of those, severe PGD developed in 44 patients (7.4%), and they received a continuous-flow external VAD (n = 17) or VA-ECMO (n = 27) support within 24 hours after transplant. We compared early and late outcomes between groups. Results Baseline characteristics were similar between groups. Implantation of the temporary VAD required longer cardiopulmonary bypass time compared with VA-ECMO (323 ± 86 minutes vs 216 ± 65 minutes, p < 0.0001). Patients who received a VAD were more likely to have longer support time (14 ± 17 days vs 5.2 ± 3.9 days, p = 0.011), a higher incidence of major bleeding requiring chest reexploration (77% vs 30%, p = 0.0047), and a higher incidence of renal failure requiring renal replacement therapy (53% vs 11%, p = 0.0045) after surgery. Overall hospital mortality was 27%. In-hospital mortality for VAD and VA-ECMO patients were 41% and 19%, respectively (p = 0.16). Ten patients (59%) were weaned from VAD support, and 24 (89%) were weaned from VA-ECMO support after adequate graft function recovery (p = 0.03). The 3-year post-transplant survival was 41% in the VAD group and 66% in the VA-ECMO group (p = 0.13). Conclusions For severe PGD, support with VA-ECMO appears to result in better clinical outcomes compared with VAD.
KW - extracorporeal membrane oxygenation
KW - heart transplantation
KW - mechanical circulatory support
KW - primary graft dysfunction
KW - ventricular assist device
UR - http://www.scopus.com/inward/record.url?scp=85009181023&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85009181023&partnerID=8YFLogxK
U2 - 10.1016/j.healun.2016.12.006
DO - 10.1016/j.healun.2016.12.006
M3 - Article
C2 - 28087104
AN - SCOPUS:85009181023
SN - 1053-2498
VL - 36
SP - 650
EP - 656
JO - Journal of Heart and Lung Transplantation
JF - Journal of Heart and Lung Transplantation
IS - 6
ER -