TY - JOUR
T1 - Impact of donor age on corneal endothelium-descemet membrane layer scroll formation
AU - Bennett, Adam
AU - Mahmoud, Shahira
AU - Drury, Donna
AU - Cavanagh, Harrison D
AU - McCulley, James P
AU - Petroll, Walter M
AU - Mootha, Venkateswara
N1 - Publisher Copyright:
© 2015 Contact Lens Association of Opthalmologists, Inc.
PY - 2015/7/9
Y1 - 2015/7/9
N2 - Objective:To correlate corneal endothelium-Descemet membrane (EDM) layer parameters of scroll tightness with donor age, endothelial cell density (ECD), and history of diabetes.Methods:Endothelium-Descemet membrane layer scrolls were harvested from 26 corneoscleral buttons using the SCUBA technique by a cornea-fellowship trained ophthalmologist masked to donor age. Two independent outcome parameters were used to characterize the scrolling severity of successfully harvested tissue: scroll width and tendency for EDM scroll formation (referred to as scroll rating on a 1-4 scale: incomplete scroll formation to tightly scrolled).Results:Mean donor age was 59±17 (15-69) years. Mean ECD of EDM scroll was 2,451±626 (range: 1,307-3,195) cells per square millimeter. Using stepwise linear regression, a significant correlation was found between scroll width and donor age (R0.497, P<0.05). Additionally, a significant inverse correlation was found between scroll width and ECD (R-0.605, P<0.05). There was no statistically significant correlation between a donor history of diabetes and the parameters of scrolling tendency.Conclusions:Our data suggest that using older donors reduces EDM scroll tightness.
AB - Objective:To correlate corneal endothelium-Descemet membrane (EDM) layer parameters of scroll tightness with donor age, endothelial cell density (ECD), and history of diabetes.Methods:Endothelium-Descemet membrane layer scrolls were harvested from 26 corneoscleral buttons using the SCUBA technique by a cornea-fellowship trained ophthalmologist masked to donor age. Two independent outcome parameters were used to characterize the scrolling severity of successfully harvested tissue: scroll width and tendency for EDM scroll formation (referred to as scroll rating on a 1-4 scale: incomplete scroll formation to tightly scrolled).Results:Mean donor age was 59±17 (15-69) years. Mean ECD of EDM scroll was 2,451±626 (range: 1,307-3,195) cells per square millimeter. Using stepwise linear regression, a significant correlation was found between scroll width and donor age (R0.497, P<0.05). Additionally, a significant inverse correlation was found between scroll width and ECD (R-0.605, P<0.05). There was no statistically significant correlation between a donor history of diabetes and the parameters of scrolling tendency.Conclusions:Our data suggest that using older donors reduces EDM scroll tightness.
KW - Descemet membrane
KW - Endothelium
KW - Keratoplasty
UR - http://www.scopus.com/inward/record.url?scp=84936891161&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84936891161&partnerID=8YFLogxK
U2 - 10.1097/ICL.0000000000000108
DO - 10.1097/ICL.0000000000000108
M3 - Article
C2 - 25603436
AN - SCOPUS:84936891161
SN - 1542-2321
VL - 41
SP - 236
EP - 239
JO - Eye and Contact Lense
JF - Eye and Contact Lense
IS - 4
ER -