TY - JOUR
T1 - Erratum to
T2 - Rapid simultaneous acquisition of macromolecular tissue volume, susceptibility, and relaxometry maps (Magnetic Resonance in Medicine, (2022), 87, 2, (781-790), 10.1002/mrm.28995)
AU - Yu, Fang Frank
AU - Huang, Susie Yi
AU - Kumar, Ashwin
AU - Witzel, Thomas
AU - Liao, Congyu
AU - Duval, Tanguy
AU - Cohen-Adad, Julien
AU - Bilgic, Berkin
N1 - Publisher Copyright:
© 2021 International Society for Magnetic Resonance in Medicine.
PY - 2022/6
Y1 - 2022/6
N2 - Dear Editors, In the abstract, the number of subjects should be changed from 3 to 4. The updated abstract sections appear below: Methods Four adults were imaged on a 3T scanner using a multi-echo 3D GRE sequence acquired at three head orientations. MTV, QSM, R2*, T1, and proton density maps were reconstructed. The sequence (GRAPPA R = 4) was also performed in subject #1 with a single head orientation, and subject #4 to assess reproducibility. Fully sampled data was acquired in subject #2, from which retrospective undersampling was performed (R = 6 GRAPPA and R = 9 JVC-GRAPPA). Prospective undersampling was performed in subject #3 (R = 6 GRAPPA and R = 9 JVC-GRAPPA) using gradient blips to shift k-space sampling in later echoes. Results Subject #1 and #4 showed that multi-orientation and single-orientation MTV maps did not differ significantly. For subject #2, the retrospectively undersampled JVC-GRAPPA and GRAPPA generated similar results as fully sampled data. This approach was validated with the prospectively undersampled images (subject #3). Combining QSM, R2*, and MTV, the contributions of myelin and iron to susceptibility was estimated. In the Methods section 2.1 of the manuscript, the number of subjects should likewise be changed from 3 to 4. The update manuscript section appears below: 2.1 | Data acquisition Four healthy adult volunteers were scanned on a 3T scanner (Siemens Skyra) with a 64-channel head coil in accordance with IRB-approved protocol.24 We regret these errors in our manuscript. CONFLICT OF INTEREST The authors do not have any conflicts of interest to report.
AB - Dear Editors, In the abstract, the number of subjects should be changed from 3 to 4. The updated abstract sections appear below: Methods Four adults were imaged on a 3T scanner using a multi-echo 3D GRE sequence acquired at three head orientations. MTV, QSM, R2*, T1, and proton density maps were reconstructed. The sequence (GRAPPA R = 4) was also performed in subject #1 with a single head orientation, and subject #4 to assess reproducibility. Fully sampled data was acquired in subject #2, from which retrospective undersampling was performed (R = 6 GRAPPA and R = 9 JVC-GRAPPA). Prospective undersampling was performed in subject #3 (R = 6 GRAPPA and R = 9 JVC-GRAPPA) using gradient blips to shift k-space sampling in later echoes. Results Subject #1 and #4 showed that multi-orientation and single-orientation MTV maps did not differ significantly. For subject #2, the retrospectively undersampled JVC-GRAPPA and GRAPPA generated similar results as fully sampled data. This approach was validated with the prospectively undersampled images (subject #3). Combining QSM, R2*, and MTV, the contributions of myelin and iron to susceptibility was estimated. In the Methods section 2.1 of the manuscript, the number of subjects should likewise be changed from 3 to 4. The update manuscript section appears below: 2.1 | Data acquisition Four healthy adult volunteers were scanned on a 3T scanner (Siemens Skyra) with a 64-channel head coil in accordance with IRB-approved protocol.24 We regret these errors in our manuscript. CONFLICT OF INTEREST The authors do not have any conflicts of interest to report.
UR - http://www.scopus.com/inward/record.url?scp=85124585723&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85124585723&partnerID=8YFLogxK
U2 - 10.1002/mrm.29158
DO - 10.1002/mrm.29158
M3 - Comment/debate
C2 - 35142389
AN - SCOPUS:85124585723
SN - 0740-3194
VL - 87
SP - 3022
EP - 3023
JO - Magnetic resonance in medicine
JF - Magnetic resonance in medicine
IS - 6
ER -