Effects of LSO detector intrisic radioactivity on SPECT imaging

Rutao Yao, Ma Tianyu, Yiping Shao

Research output: Chapter in Book/Report/Conference proceedingConference contribution

5 Scopus citations

Abstract

This work was part of a feasibility study of developing SPECT imaging capability on a lutetium oxyorthosilicate (LSO)-based animal PET system. The SPECT aspect of the system was enabled by inserting a collimator assembly inside the detector ring and acquiring data in singles mode. The LSO detectors were used for both PET and SPECT imaging. The intrinsic radioactivity of 176Lu in the LSO crystals, however, contaminates the SPECT data more severely than for PET imaging. This work was to study the imaging characteristics of the intrinsic LSO activity, the effects of correction, and the minimal activity level required for usable SPECT imaging. To understand the structural and noise patterns of LSO activity in images, measured high counts projections from LSO activity only and simulated multiple-replicates of low counts projections from LSO activity with and without a uniform phantom in the fleld-of-view (FOV) were reconstructed. To identify the minimal activity levels needed for obtaining useful tomographic images with the existence of LSO activity, we derived a formula to estimate the minimal activity in the FOV of one detector crystal ring that would yield a net detectable signal in projection data. A series of phantoms with different activity distribution patterns and total activity levels were scanned for variable length of time through simulation and experiments. The LSO contributions to each study were estimated from a long LSO background acquisition dataset and corrected prior to iterative image reconstruction. The LSO activity showed up as concentric rings in a reconstructed tomographic image. The LSO activity estimation and correction method was effective and it reduced the activity level required for producing images with expected visual patterns to about 1/4 of the level needed without the correction. The minimal activity levels predicted by the projection data based formula correlated well with the activity levels needed for obtaining visible image patterns observed in simulated and experimental studies. Phantom studies demonstrated that while ¡mage quality was dependent on source distribution pattern, activity level, and acquisition time, SPECT imaging on LSO based animal PET is feasible with practical dose level and acquisition time used in animal imaging.

Original languageEnglish (US)
Title of host publication2007 IEEE Nuclear Science Symposium and Medical Imaging Conference, NSS-MIC
Pages4497-4502
Number of pages6
DOIs
StatePublished - 2007
Event2007 IEEE Nuclear Science Symposium and Medical Imaging Conference, NSS-MIC - Honolulu, HI, United States
Duration: Oct 27 2007Nov 3 2007

Publication series

NameIEEE Nuclear Science Symposium Conference Record
Volume6
ISSN (Print)1095-7863

Other

Other2007 IEEE Nuclear Science Symposium and Medical Imaging Conference, NSS-MIC
Country/TerritoryUnited States
CityHonolulu, HI
Period10/27/0711/3/07

ASJC Scopus subject areas

  • Radiation
  • Nuclear and High Energy Physics
  • Radiology Nuclear Medicine and imaging

Fingerprint

Dive into the research topics of 'Effects of LSO detector intrisic radioactivity on SPECT imaging'. Together they form a unique fingerprint.

Cite this