T1 - Dual-layer spectral computerized tomography for metal artifact reduction
T2 - small versus large orthopedic devices
AU - Kosmas, Christos
AU - Hojjati, Mojgan
AU - Young, Peter C.
AU - Abedi, Aidin
AU - Gholamrezanezhad, Ali
AU - Rajiah, Prabhakar
PY - 2019/1/1
Y1 - 2019/1/1
N2 - Introduction: Metal artifacts limit the diagnostic utility of computerized tomography (CT) for implant-related complications. Dual-layer spectral detector CT imaging has been suggested for artifact reduction. Our objective was to evaluate the utility of spectral CT in artifact reduction in patients with small and large metal implants. Methods: In this prospective study, patients with metallic orthopedic implants underwent CT imaging using a prototype spectral detector CT scanner. Conventional images were generated with iterative reconstruction at 120 kVp, and virtual monochromatic images were generated at 20-keV intervals between 40 to 200 keV. Conventional and monochromatic images were compared quantitatively using signal-to-noise ratio (SNR) and artifact improvement. Qualitative analysis was performed independently by two musculoskeletal radiologists and included six image quality indicators. Results: A total of 12 patients were scanned. In monochromatic images, as the energy level increased, the artifact size decreased progressively (p < 0.01). When conventional and monochromatic images were compared, maximum reduction was seen at 200 keV. Using qualitative assessments, 160 and 180 keV levels had the best overall diagnostic image quality. With increased energy level, there was improvement in qualitative ratings of bone-metal interface conspicuity (p = 0.002), degree of streak artifact (p = 0.010) and trabecular bone definition at 1 cm from implant (p = 0.023), and a trend towards significance for bone definition at 5 cm, soft tissue detail and overall diagnostic quality. Subgroup analysis revealed superior artifact reduction in small implants compared to large hardware. Discussion: Our results support the utility of dual-layer spectral CT in metal artifact reduction. Virtual monochromatic images were diagnostically superior, especially for smaller implants. Virtual monoenergetic images at 160–180 keV are ideal for reducing artifacts.
AB - Introduction: Metal artifacts limit the diagnostic utility of computerized tomography (CT) for implant-related complications. Dual-layer spectral detector CT imaging has been suggested for artifact reduction. Our objective was to evaluate the utility of spectral CT in artifact reduction in patients with small and large metal implants. Methods: In this prospective study, patients with metallic orthopedic implants underwent CT imaging using a prototype spectral detector CT scanner. Conventional images were generated with iterative reconstruction at 120 kVp, and virtual monochromatic images were generated at 20-keV intervals between 40 to 200 keV. Conventional and monochromatic images were compared quantitatively using signal-to-noise ratio (SNR) and artifact improvement. Qualitative analysis was performed independently by two musculoskeletal radiologists and included six image quality indicators. Results: A total of 12 patients were scanned. In monochromatic images, as the energy level increased, the artifact size decreased progressively (p < 0.01). When conventional and monochromatic images were compared, maximum reduction was seen at 200 keV. Using qualitative assessments, 160 and 180 keV levels had the best overall diagnostic image quality. With increased energy level, there was improvement in qualitative ratings of bone-metal interface conspicuity (p = 0.002), degree of streak artifact (p = 0.010) and trabecular bone definition at 1 cm from implant (p = 0.023), and a trend towards significance for bone definition at 5 cm, soft tissue detail and overall diagnostic quality. Subgroup analysis revealed superior artifact reduction in small implants compared to large hardware. Discussion: Our results support the utility of dual-layer spectral CT in metal artifact reduction. Virtual monochromatic images were diagnostically superior, especially for smaller implants. Virtual monoenergetic images at 160–180 keV are ideal for reducing artifacts.
KW - Artifact
KW - Dual-energy computed tomography
KW - Dual-layer detector
KW - Hip replacement arthroplasty
KW - Metal implant
KW - Spinal instrumentation
KW - Virtual monoenergetic images
UR - http://www.scopus.com/inward/record.url?scp=85066622769&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85066622769&partnerID=8YFLogxK
U2 - 10.1007/s00256-019-03248-3
DO - 10.1007/s00256-019-03248-3
M3 - Article
C2 - 31154493
AN - SCOPUS:85066622769
SN - 0364-2348
JO - Skeletal Radiology
JF - Skeletal Radiology
ER -