Development of a multi-purpose quality control phantom for MRI-based treatment planning in high-dose-rate brachytherapy of cervical cancer

Abolfazl Kanani, Amir Owrangi, Mehran Yazdi, Ali Fatemi-Ardekani, Mohammad Amin Mosleh-Shirazi

Research output: Contribution to journalArticlepeer-review

1 Scopus citations

Abstract

Purpose: Suitable commissioning and quality control (QC) tests for high-dose-rate brachytherapy (HDR-BT) is necessary to ensure dosimetric and geometric accuracy of the treatment. This study aimed to present the methodology of developing a novel multi-purpose QC phantom (AQuA-BT) and examples of its’ application in 3D image-based (particularly magnetic resonance imaging [MRI]-based) planning for cervix BT. Material and methods: Design criteria led to a phantom with sufficient size waterproof box for dosimetry and capability for inserting other components inside the phantom for: (A) Validating dose calculation algorithms in treatment planning systems (TPSs) using a small-volume ionization chamber; (B) Testing volume calculation accuracy in TPSs for bladder, rectum, and sigmoid organs at risk (OARs) constructed by 3D printing; (C) Quantification of MRI distortions using 17 semi-elliptical plates with 4,317 control points to mimic a realistic female’s pelvis size; and (D) Quantification of image distortions and artifacts induced by MRI-compatible applicators using a specific radial fiducial marker. The utility of the phantom was tested in various QC procedures. Results: The phantom was successfully implemented for examples of intended QC procedures. The maximum deviation between the absorbed doses to water assessed with our phantom and those calculated by SagiPlan TPS was 1.7%. The mean discrepancy in volumes of TPS-calculated OARs was 1.1%. The differences between known distances within the phantom on MR imaging were within 0.7 mm compared with computed tomography. Conclusions: This phantom is a promising useful tool for dosimetric and geometric quality assurance (QA) in MRI-based cervix BT.

Original languageEnglish (US)
Pages (from-to)57-68
Number of pages12
JournalJournal of Contemporary Brachytherapy
Volume15
Issue number1
DOIs
StatePublished - 2023

Keywords

  • HDR brachytherapy
  • MRI-based planning
  • commissioning
  • phantom
  • quality assurance

ASJC Scopus subject areas

  • Oncology
  • Radiology Nuclear Medicine and imaging

Fingerprint