TY - JOUR
T1 - Delayed febrile response with bloodstream infections in patients with continuous-flow left ventricular assist devices
AU - Wrobel, Christopher A.
AU - Drazner, Mark H.
AU - Ayers, Colby R
AU - Pham, David D.
AU - La Hoz, Ricardo M.
AU - Grodin, Justin L.
AU - Garg, Sonia
AU - Mammen, Pradeep P.A.
AU - Morlend, Robert M.
AU - Araj, Faris
AU - Amin, Alpesh A.
AU - Cornwell, William K.
AU - Thibodeau, Jennifer T.
N1 - Funding Information:
Funding MHD acknowledges support from the James M Wooten Chair in Cardiology. WKC receives funding from an NIH/NHLBI mentored patient-oriented research career development award (1K23HL132048-01). RMLH receives support from the National Center for Advancing Translational Sciences of the National Institutes of Health under award number UL1TR001105. There are no relationships with industry.
Publisher Copyright:
© American Federation for Medical Research 2019.
PY - 2019/3/1
Y1 - 2019/3/1
N2 - Bloodstream infections (BSIs) are common in patients with continuous-flow left ventricular assist devices (CF-LVADs). Whether CF-LVADs modulate the febrile response to BSIs is unknown. We retrospectively compared the febrile response to BSIs in patients with heart failure (HF) with CF-LVADs versus a control population of patients with HF receiving inotropic infusions. BSIs were adjudicated using the Centers for Disease Control and Prevention and the National Healthcare Safety Network criteria. Febrile status (temperature ≥38°C, 100.4 °F), temperature at presentation with BSI, and the highest temperature within 72 hours (Tmax) were collected. We observed 59 BSIs in LVAD patients and 45 BSIs in controls. LVAD patients were more likely to be afebrile and to have a lower temperature at presentation than control (88% vs 58%, p=0.002, and 37°C ±0.7 vs 37.7°C ±1.0, p=0.0009, respectively). By 72 hours, the difference in afebrile status diminished (53% vs 44%, p=0.42), and the Tmax was similar between the LVAD and control groups (37.9°C±0.9 vs 38.2°C±0.8, respectively, p=0.10). In conclusion, at presentation with a BSI, the vast majority of CF-LVAD patients were afebrile, an event which occurred at a higher frequency when compared with patients with advanced HF on chronic inotropes via an indwelling venous catheter. These data alert clinicians to have a very low threshold to obtain blood cultures in CF-LVAD patients even in the absence of fever. Further study is needed to determine whether a delayed or diminished febrile response represents another pathophysiological consequence of CF-LVADs.
AB - Bloodstream infections (BSIs) are common in patients with continuous-flow left ventricular assist devices (CF-LVADs). Whether CF-LVADs modulate the febrile response to BSIs is unknown. We retrospectively compared the febrile response to BSIs in patients with heart failure (HF) with CF-LVADs versus a control population of patients with HF receiving inotropic infusions. BSIs were adjudicated using the Centers for Disease Control and Prevention and the National Healthcare Safety Network criteria. Febrile status (temperature ≥38°C, 100.4 °F), temperature at presentation with BSI, and the highest temperature within 72 hours (Tmax) were collected. We observed 59 BSIs in LVAD patients and 45 BSIs in controls. LVAD patients were more likely to be afebrile and to have a lower temperature at presentation than control (88% vs 58%, p=0.002, and 37°C ±0.7 vs 37.7°C ±1.0, p=0.0009, respectively). By 72 hours, the difference in afebrile status diminished (53% vs 44%, p=0.42), and the Tmax was similar between the LVAD and control groups (37.9°C±0.9 vs 38.2°C±0.8, respectively, p=0.10). In conclusion, at presentation with a BSI, the vast majority of CF-LVAD patients were afebrile, an event which occurred at a higher frequency when compared with patients with advanced HF on chronic inotropes via an indwelling venous catheter. These data alert clinicians to have a very low threshold to obtain blood cultures in CF-LVAD patients even in the absence of fever. Further study is needed to determine whether a delayed or diminished febrile response represents another pathophysiological consequence of CF-LVADs.
KW - Bacterial Infections
KW - Heart Failure
KW - Heart-assist Devices
UR - http://www.scopus.com/inward/record.url?scp=85060777988&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85060777988&partnerID=8YFLogxK
U2 - 10.1136/jim-2018-000893
DO - 10.1136/jim-2018-000893
M3 - Article
C2 - 30696751
AN - SCOPUS:85060777988
SN - 1081-5589
VL - 67
SP - 653
EP - 658
JO - Journal of Investigative Medicine
JF - Journal of Investigative Medicine
IS - 3
ER -