TY - JOUR
T1 - Combination of a sub-3 μm superficially porous particle packed column with charged aerosol detection for the simple and sensitive measurement of nine macrolides in human urine
AU - Jia, Shaodong
AU - Song, In Gi
AU - Jeong, Kyung Min
AU - Li, Jing
AU - Park, Jeong Hill
AU - Lee, Jeongmi
AU - Kwon, Sung Won
PY - 2014/10/1
Y1 - 2014/10/1
N2 - Due to the lack of chromophores in many macrolides, analytical methods based on mass spectrometry and electrochemical detection coupled to liquid chromatography have been suggested to be suitable for the quantification of macrolides in complex matrices. In this study, a simple and sensitive analytical method was established for the simultaneous measurement of nine macrolides in human urine by combining a sub-3 μm superficially porous particle packed column with charged aerosol detection. After thorough investigation of various sample preparation methods, including two liquid-liquid extraction methods and four solid-phase extraction methods, HLB solid-phase extraction was selected and further optimized. Absolute recovery of the optimized sample preparation method ranged from 99.5-110.2%, indicating its very high extraction/clean-up efficiency. For chromatography, parameters influencingmacrolide separation were systematically optimized, and the resulting conditions allowed baseline separation of nine macrolides within 24 min using a very simple mobile phase. The established method was validated for linearity, limit of detection, limit of quantification, absolute recovery, and precision. Based on its limit of detection (0.025-0.100 μg/mL), the method had similar or greater sensitivity than most methods based on electrochemical detection. It was found that the current method was appropriate for application to real human urine samples after drug administration.
AB - Due to the lack of chromophores in many macrolides, analytical methods based on mass spectrometry and electrochemical detection coupled to liquid chromatography have been suggested to be suitable for the quantification of macrolides in complex matrices. In this study, a simple and sensitive analytical method was established for the simultaneous measurement of nine macrolides in human urine by combining a sub-3 μm superficially porous particle packed column with charged aerosol detection. After thorough investigation of various sample preparation methods, including two liquid-liquid extraction methods and four solid-phase extraction methods, HLB solid-phase extraction was selected and further optimized. Absolute recovery of the optimized sample preparation method ranged from 99.5-110.2%, indicating its very high extraction/clean-up efficiency. For chromatography, parameters influencingmacrolide separation were systematically optimized, and the resulting conditions allowed baseline separation of nine macrolides within 24 min using a very simple mobile phase. The established method was validated for linearity, limit of detection, limit of quantification, absolute recovery, and precision. Based on its limit of detection (0.025-0.100 μg/mL), the method had similar or greater sensitivity than most methods based on electrochemical detection. It was found that the current method was appropriate for application to real human urine samples after drug administration.
KW - Charged aerosol detection
KW - Macrolides
KW - Solid-phase extraction
KW - Superficially porous particles
KW - Urine analysis
UR - http://www.scopus.com/inward/record.url?scp=84907998242&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84907998242&partnerID=8YFLogxK
U2 - 10.1002/jssc.201400517
DO - 10.1002/jssc.201400517
M3 - Article
C2 - 25155847
AN - SCOPUS:84907998242
SN - 1615-9306
VL - 37
SP - 2837
EP - 2843
JO - Journal of Separation Science
JF - Journal of Separation Science
IS - 20
ER -