TY - JOUR
T1 - Clinical exome studies have inconsistent coverage
AU - Gotway, Garrett
AU - Crossley, Eric
AU - Kozlitina, Julia
AU - Xing, Chao
AU - Fan, Judy
AU - Hornbuckle, Callie
AU - Thies, Jenny
AU - Michel, Donnice
AU - Quinn, Christine
AU - Scheuerle, Angela E.
AU - Umana, Luis A.
AU - Uhles, Crescenda L.
AU - Park, Jason Y.
PY - 2020
Y1 - 2020
N2 - BACKGROUND: Exome sequencing has become a commonly used clinical diagnostic test. Multiple studies have examined the diagnostic utility and individual laboratory performance of exome testing; however, no previous study has surveyed and compared the data quality from multiple clinical laboratories. METHODS: We examined sequencing data from 36 clinical exome tests from 3 clinical laboratories. Exome data were compared in terms of overall characteristics and coverage of specific genes and nucleotide positions. The sets of genes examined included genes in Consensus Coding Sequence (CCDS) (n = 17 723), a subset of genes clinically relevant to epilepsy (n = 108), and genes that are recommended for reporting of secondary findings (n = 57; excludes X-linked genes). RESULTS: The average exome nucleotide coverage (≥20×) of each laboratory varied at 96.49% (CV = 3%), 96.54% (CV = 1%), and 91.68% (CV = 4%), for laboratories A, B, and C, respectively. For CCDS genes, the average number of completely covered genes varied at 12 184 (CV = 29%), 11 687 (CV = 13%), and 5989 (CV = 37%), for laboratories A, B, and C, respectively. With smaller subsets of genes related to epilepsy and secondary findings, the CV revealed low consistency, with a maximum CV seen in laboratory C for both epilepsy genes (CV = 60%) and secondary findings genes (CV = 71%). CONCLUSIONS: Poor consistency in complete gene coverage was seen in the clinical exome laboratories surveyed. The degree of consistency varied widely between the laboratories.
AB - BACKGROUND: Exome sequencing has become a commonly used clinical diagnostic test. Multiple studies have examined the diagnostic utility and individual laboratory performance of exome testing; however, no previous study has surveyed and compared the data quality from multiple clinical laboratories. METHODS: We examined sequencing data from 36 clinical exome tests from 3 clinical laboratories. Exome data were compared in terms of overall characteristics and coverage of specific genes and nucleotide positions. The sets of genes examined included genes in Consensus Coding Sequence (CCDS) (n = 17 723), a subset of genes clinically relevant to epilepsy (n = 108), and genes that are recommended for reporting of secondary findings (n = 57; excludes X-linked genes). RESULTS: The average exome nucleotide coverage (≥20×) of each laboratory varied at 96.49% (CV = 3%), 96.54% (CV = 1%), and 91.68% (CV = 4%), for laboratories A, B, and C, respectively. For CCDS genes, the average number of completely covered genes varied at 12 184 (CV = 29%), 11 687 (CV = 13%), and 5989 (CV = 37%), for laboratories A, B, and C, respectively. With smaller subsets of genes related to epilepsy and secondary findings, the CV revealed low consistency, with a maximum CV seen in laboratory C for both epilepsy genes (CV = 60%) and secondary findings genes (CV = 71%). CONCLUSIONS: Poor consistency in complete gene coverage was seen in the clinical exome laboratories surveyed. The degree of consistency varied widely between the laboratories.
UR - http://www.scopus.com/inward/record.url?scp=85077650102&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85077650102&partnerID=8YFLogxK
U2 - 10.1093/clinchem.2019.306795
DO - 10.1093/clinchem.2019.306795
M3 - Article
C2 - 32609854
AN - SCOPUS:85077650102
SN - 0009-9147
VL - 66
SP - 199
EP - 206
JO - Clinical chemistry
JF - Clinical chemistry
IS - 1
ER -