TY - GEN
T1 - Chronic sensory-motor activity in behaving animals using regenerative multi-electrode interfaces
AU - Desai, V. H.
AU - Anand, S.
AU - Tran, M.
AU - Kanneganti, A.
AU - Vasudevan, S.
AU - Seifert, J. L.
AU - Cheng, J.
AU - Keefer, E. W.
AU - Romero-Ortega, M. I.
N1 - Publisher Copyright:
© 2014 IEEE.
PY - 2014/11/2
Y1 - 2014/11/2
N2 - Regenerative peripheral nerve interfaces have been proposed as viable alternatives for the natural control and feel of robotic prosthetic limbs. We have developed a Regenerative Multi-electrode Interface (REMI) that guides re-growing axons through an electrode array deployed in the lumen of a nerve guide. While acute studies have shown the use of the REMI in the rat sciatic nerve, the quality of chronic signal recording has not been reported. Here we show that implantation of this interface in the sciatic nerve is stable with high quality recordings up to 120 days and failures mainly attributable to abiotic factors related to pedestal detachment and wire breakage. We further tested the interfacing of REMI with fascicles of the sciatic nerve that primarily innervate muscles (tibial) and skin (sural). When implanted into the tibial nerve, bursting activity was observed synchronous to stepping. However, implantation of REMI into the sural nerve failed due to its small size. While fascicles smaller than 300 μm are a challenge for regenerative interfacing, we show that a modified REMI can be used in an insertion mode to record sensory signals from skin. In summary, the REMI represents an effective tool for recording firing patterns of specific axon types during voluntary movement, which may be used to improve the motor control and sensory feedback in closed loop control systems for robotic prosthesis.
AB - Regenerative peripheral nerve interfaces have been proposed as viable alternatives for the natural control and feel of robotic prosthetic limbs. We have developed a Regenerative Multi-electrode Interface (REMI) that guides re-growing axons through an electrode array deployed in the lumen of a nerve guide. While acute studies have shown the use of the REMI in the rat sciatic nerve, the quality of chronic signal recording has not been reported. Here we show that implantation of this interface in the sciatic nerve is stable with high quality recordings up to 120 days and failures mainly attributable to abiotic factors related to pedestal detachment and wire breakage. We further tested the interfacing of REMI with fascicles of the sciatic nerve that primarily innervate muscles (tibial) and skin (sural). When implanted into the tibial nerve, bursting activity was observed synchronous to stepping. However, implantation of REMI into the sural nerve failed due to its small size. While fascicles smaller than 300 μm are a challenge for regenerative interfacing, we show that a modified REMI can be used in an insertion mode to record sensory signals from skin. In summary, the REMI represents an effective tool for recording firing patterns of specific axon types during voluntary movement, which may be used to improve the motor control and sensory feedback in closed loop control systems for robotic prosthesis.
UR - http://www.scopus.com/inward/record.url?scp=84929492369&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84929492369&partnerID=8YFLogxK
U2 - 10.1109/EMBC.2014.6944000
DO - 10.1109/EMBC.2014.6944000
M3 - Conference contribution
C2 - 25570368
AN - SCOPUS:84929492369
T3 - 2014 36th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBC 2014
SP - 1973
EP - 1976
BT - 2014 36th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBC 2014
PB - Institute of Electrical and Electronics Engineers Inc.
T2 - 2014 36th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBC 2014
Y2 - 26 August 2014 through 30 August 2014
ER -