TY - JOUR
T1 - Breast implant-associated anaplastic large cell lymphoma
T2 - Sensitivity, specificity, and findings of imaging studies in 44 patients
AU - Adrada, Beatriz E.
AU - Miranda, Roberto N.
AU - Rauch, Gaiane Margishvili
AU - Arribas, Elsa
AU - Kanagal-Shamanna, Rashmi
AU - Clemens, Mark W.
AU - Fanale, Michelle
AU - Haideri, Nisreen
AU - Mustafa, Eid
AU - Larrinaga, John
AU - Reisman, Neal R.
AU - Jaso, Jesse
AU - You, M. James
AU - Young, Ken H.
AU - Medeiros, L. Jeffrey
AU - Yang, Wei
PY - 2014/8
Y1 - 2014/8
N2 - Breast implant-associated anaplastic large cell lymphoma (BIA ALCL) is a newly described clinicopathologic entity. The purpose of this study is to describe the imaging findings of patients with BIA ALCL and determine their sensitivity and specificity in the detection of the presence of an effusion or a mass related to BIA ALCL. A retrospective search was performed of our files as well as of the world literature for patients with pathologically proven BIA ALCL who had been assessed by any imaging study including ultrasound (US), computerized tomography (CT), magnetic resonance imaging (MRI), or positron emission tomography (PET)-CT, as well as mammography. The sensitivity and specificity of each imaging modality in the detection of an effusion or a mass around breast implants was determined. We identified 44 patients who had BIA ALCL and imaging studies performed between 1997 and 2013. The sensitivity for detecting an effusion was 84, 55, 82, and 38 %, and for detecting a mass was 46, 50, 50, and 64 %, by US, CT, MRI, and PET, respectively. The sensitivity of mammography in the detection of an abnormality without distinction of effusion or mass was 73 %, and specificity 50 %. Progression-free survival was worse in patients with an implant-associated mass (p = 0.001). Conclusions: Current imaging with US, CT, MR, and PET appears suboptimal in the detection of an imaging abnormality associated with BIA ALCL. This under diagnosis may reflect a lack of awareness of this rare entity suggesting the need for better understanding of the spectrum of imaging findings associated with BIA ALCL by breast imagers.
AB - Breast implant-associated anaplastic large cell lymphoma (BIA ALCL) is a newly described clinicopathologic entity. The purpose of this study is to describe the imaging findings of patients with BIA ALCL and determine their sensitivity and specificity in the detection of the presence of an effusion or a mass related to BIA ALCL. A retrospective search was performed of our files as well as of the world literature for patients with pathologically proven BIA ALCL who had been assessed by any imaging study including ultrasound (US), computerized tomography (CT), magnetic resonance imaging (MRI), or positron emission tomography (PET)-CT, as well as mammography. The sensitivity and specificity of each imaging modality in the detection of an effusion or a mass around breast implants was determined. We identified 44 patients who had BIA ALCL and imaging studies performed between 1997 and 2013. The sensitivity for detecting an effusion was 84, 55, 82, and 38 %, and for detecting a mass was 46, 50, 50, and 64 %, by US, CT, MRI, and PET, respectively. The sensitivity of mammography in the detection of an abnormality without distinction of effusion or mass was 73 %, and specificity 50 %. Progression-free survival was worse in patients with an implant-associated mass (p = 0.001). Conclusions: Current imaging with US, CT, MR, and PET appears suboptimal in the detection of an imaging abnormality associated with BIA ALCL. This under diagnosis may reflect a lack of awareness of this rare entity suggesting the need for better understanding of the spectrum of imaging findings associated with BIA ALCL by breast imagers.
KW - Anaplastic large cell lymphoma
KW - Breast implant
KW - Imaging
KW - MRI
KW - Mammography
KW - PET
KW - Ultrasound
UR - http://www.scopus.com/inward/record.url?scp=84906060403&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84906060403&partnerID=8YFLogxK
U2 - 10.1007/s10549-014-3034-3
DO - 10.1007/s10549-014-3034-3
M3 - Review article
C2 - 25073777
AN - SCOPUS:84906060403
SN - 0167-6806
VL - 147
SP - 1
EP - 14
JO - Breast Cancer Research and Treatment
JF - Breast Cancer Research and Treatment
IS - 1
ER -