TY - JOUR
T1 - Baroreceptor unloading does not limit forearm sweat rate during severe passive heat stress
AU - Schlader, Zachary J.
AU - Gagnon, Daniel
AU - Lucas, Rebekah A I
AU - Pearson, James
AU - Crandall, Craig G.
N1 - Publisher Copyright:
Copyright © 2015 the American Physiological Society
PY - 2015/2/1
Y1 - 2015/2/1
N2 - This study tested the hypothesis that sweat rate during passive heat stress is limited by baroreceptor unloading associated with heat stress. Two protocols were performed in which healthy subjects underwent passive heat stress that elicited an increase in intestinal temperature of ∼1.8°C. Upon attaining this level of hyperthermia, in protocol 1 (n = 10, 3 females) a bolus (19 ml/kg) of warm (∼38°C) isotonic saline was rapidly (5-10 min) infused intravenously to elevate central venous pressure (CVP), while in protocol 2 (n = 11, 5 females) phenylephrine was infused intravenously (60-120 μg/min) to return mean arterial pressure (MAP) to normothermic levels. In protocol 1, heat stress reduced CVP from 3.9 ± 1.9 mmHg (normothermia) to -0.6 ± 1.4 mmHg (P < 0.001), while saline infusion returned CVP to normothermic levels (5.1 ± 1.7 mmHg; P > 0.999). Sweat rate was elevated by heat stress (1.21 ± 0.44 mg·cm-2·min-1) but remained unchanged during rapid saline infusion (1.26 ± 0.47 mg·cm-2·min-1, P = 0.5), whereas cutaneous vascular conductance increased from 77 ± 10 to 101 ± 20% of local heating max (P = 0.029). In protocol 2, MAP was reduced with heat stress from 85 ± 7 mmHg to 76 ± 8 mmHg (P = 0.048). Although phenylephrine infusion returned MAP to normothermic levels (88 ± 7 mmHg; P > 0.999), sweat rate remained unchanged during phenylephrine infusion (1.39 ± 0.22 vs. 1.41 ± 0.24 mg·cm-2·min-1; P > 0.999). These data indicate that both cardiopulmonary and arterial baroreceptor unloading do not limit increases in sweat rate during passive heat stress.
AB - This study tested the hypothesis that sweat rate during passive heat stress is limited by baroreceptor unloading associated with heat stress. Two protocols were performed in which healthy subjects underwent passive heat stress that elicited an increase in intestinal temperature of ∼1.8°C. Upon attaining this level of hyperthermia, in protocol 1 (n = 10, 3 females) a bolus (19 ml/kg) of warm (∼38°C) isotonic saline was rapidly (5-10 min) infused intravenously to elevate central venous pressure (CVP), while in protocol 2 (n = 11, 5 females) phenylephrine was infused intravenously (60-120 μg/min) to return mean arterial pressure (MAP) to normothermic levels. In protocol 1, heat stress reduced CVP from 3.9 ± 1.9 mmHg (normothermia) to -0.6 ± 1.4 mmHg (P < 0.001), while saline infusion returned CVP to normothermic levels (5.1 ± 1.7 mmHg; P > 0.999). Sweat rate was elevated by heat stress (1.21 ± 0.44 mg·cm-2·min-1) but remained unchanged during rapid saline infusion (1.26 ± 0.47 mg·cm-2·min-1, P = 0.5), whereas cutaneous vascular conductance increased from 77 ± 10 to 101 ± 20% of local heating max (P = 0.029). In protocol 2, MAP was reduced with heat stress from 85 ± 7 mmHg to 76 ± 8 mmHg (P = 0.048). Although phenylephrine infusion returned MAP to normothermic levels (88 ± 7 mmHg; P > 0.999), sweat rate remained unchanged during phenylephrine infusion (1.39 ± 0.22 vs. 1.41 ± 0.24 mg·cm-2·min-1; P > 0.999). These data indicate that both cardiopulmonary and arterial baroreceptor unloading do not limit increases in sweat rate during passive heat stress.
KW - Arterial baroreceptors
KW - Cardiopulmonary baroreceptors
KW - Central venous pressure
KW - Hyperthermia
KW - Skin blood flow
KW - Sweat rate
UR - http://www.scopus.com/inward/record.url?scp=84922962540&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84922962540&partnerID=8YFLogxK
U2 - 10.1152/japplphysiol.00800.2014
DO - 10.1152/japplphysiol.00800.2014
M3 - Article
C2 - 25525210
AN - SCOPUS:84922962540
SN - 0161-7567
VL - 118
SP - 449
EP - 454
JO - Journal of Applied Physiology
JF - Journal of Applied Physiology
IS - 4
ER -