T1 - Auto-fluorescence lifetime and light reflectance spectroscopy for breast cancer diagnosis
T2 - Potential tools for intraoperative margin detection
AU - Sharma, Vikrant
AU - Shivalingaiah, Shivaranjani
AU - Peng, Yan
AU - Euhus, David
AU - Gryczynski, Zygmunt
AU - Liu, Hanli
PY - 2012/8/1
Y1 - 2012/8/1
N2 - This study investigates the use of two spectroscopic techniques, auto-fluorescence lifetime measurement (AFLM) and light reflectance spectroscopy (LRS), for detecting invasive ductal carcinoma (IDC) in human ex vivo breast specimens. AFLM used excitation at 447 nm with multiple emission wavelengths (532, 562, 632, and 644 nm), at which auto-fluorescence lifetimes and their weight factors were analyzed using a double exponent model. LRS measured reflectance spectra in the range of 500-840 nm and analyzed the spectral slopes empirically at several distinct spectral regions. Our preliminary results based on 93 measured locations (i.e., 34 IDC, 31 benign fibrous, 28 adipose) from 6 specimens show significant differences in 5 AFLM-derived parameters and 9 LRS-based spectral slopes between benign and malignant breast samples. Multinomial logistic regression with a 10-fold cross validation approach was implemented with selected features to classify IDC from benign fibrous and adipose tissues for the two techniques independently as well as for the combined dual-modality approach. The accuracy for classifying IDC was found to be 96.4 ± 0.8%, 92.3 ± 0.8% and 96 ± 1.3% for LRS, AFLM, and dual-modality, respectively.
AB - This study investigates the use of two spectroscopic techniques, auto-fluorescence lifetime measurement (AFLM) and light reflectance spectroscopy (LRS), for detecting invasive ductal carcinoma (IDC) in human ex vivo breast specimens. AFLM used excitation at 447 nm with multiple emission wavelengths (532, 562, 632, and 644 nm), at which auto-fluorescence lifetimes and their weight factors were analyzed using a double exponent model. LRS measured reflectance spectra in the range of 500-840 nm and analyzed the spectral slopes empirically at several distinct spectral regions. Our preliminary results based on 93 measured locations (i.e., 34 IDC, 31 benign fibrous, 28 adipose) from 6 specimens show significant differences in 5 AFLM-derived parameters and 9 LRS-based spectral slopes between benign and malignant breast samples. Multinomial logistic regression with a 10-fold cross validation approach was implemented with selected features to classify IDC from benign fibrous and adipose tissues for the two techniques independently as well as for the combined dual-modality approach. The accuracy for classifying IDC was found to be 96.4 ± 0.8%, 92.3 ± 0.8% and 96 ± 1.3% for LRS, AFLM, and dual-modality, respectively.
UR - http://www.scopus.com/inward/record.url?scp=84865618409&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84865618409&partnerID=8YFLogxK
U2 - 10.1364/BOE.3.001825
DO - 10.1364/BOE.3.001825
M3 - Article
C2 - 22876347
AN - SCOPUS:84865618409
SN - 2156-7085
VL - 3
SP - 1825
EP - 1840
JO - Biomedical Optics Express
JF - Biomedical Optics Express
IS - 8
ER -