Association between indices of prosthesis internal orifice size and operative mortality after isolated aortic valve replacement

Charles R. Bridges, Sean M. O'Brien, Joseph C. Cleveland, Edward B. Savage, James S. Gammie, Fred H. Edwards, Eric D. Peterson, Frederick L. Grover

Research output: Contribution to journalArticlepeer-review

25 Scopus citations

Abstract

Objectives: The appropriate index of prosthesis internal orifice size and its effect on operative mortality after aortic valve replacement are controversial. We examined the association between several relevant indices and patient size on operative mortality. Indices examined included projected in vivo effective orifice area and geometric orifice area, with patient size defined as body surface area. Methods: A review of the Society of Thoracic Surgeons National Cardiac Database (2000-2004) yielded 48,722 patients who had isolated aortic valve replacement. This analysis is based on the cohort of 42,310 patients with the 8 most prevalent valve types with manufacturer's labeled sizes 19 mm through 29 mm. Multivariable logistic regression models were employed to determine the effects of body surface area, effective orifice area, geometric orifice area, and selected derived indices (eg, effective orifice area/body surface area) on risk-adjusted operative mortality. Results: In separate multivariable models, effective orifice area and geometric orifice area were both inversely correlated with operative mortality. However, an unanticipated finding was that with either effective orifice area or geometric orifice area held constant, body surface area was significantly and inversely correlated with operative mortality. When patients were stratified by effective orifice area, geometric orifice area, or manufacturer's labeled valve size and type, elevations in body surface area were associated with a decrease rather than an increase in operative mortality. Conclusions: Prostheses with small geometric orifice area or small effective orifice area are associated with increased operative mortality after isolated aortic valve replacement. Even for valves with small effective orifice area, however, mortality decreases as body surface area increases. With respect to operative mortality, therefore, our results do not support using arbitrary cutoff values of effective orifice area/body surface area to determine the valve to utilize in a given patient.

Original languageEnglish (US)
Pages (from-to)1012-1021.e2
JournalJournal of Thoracic and Cardiovascular Surgery
Volume133
Issue number4
DOIs
StatePublished - Apr 2007
Externally publishedYes

ASJC Scopus subject areas

  • Surgery
  • Pulmonary and Respiratory Medicine
  • Cardiology and Cardiovascular Medicine

Fingerprint

Dive into the research topics of 'Association between indices of prosthesis internal orifice size and operative mortality after isolated aortic valve replacement'. Together they form a unique fingerprint.

Cite this