TY - JOUR
T1 - Assessment of the GlideScope spectrum single-use video laryngoscope blades and small GlideRite stylet for use in pediatrics
T2 - A randomized manikin study
AU - Kiss, Edgar E.
AU - Khan, Asif
AU - Steiner, Jeffrey W.
AU - Szmuk, Peter
AU - Olomu, Patrick N.
N1 - Funding Information:
We thank Roxana Ploski, B.S. and Allison Griffin, M.S. for their help with data collection and logistics for this study. We would also like to thank Abu Taher Minhajuddin, Ph. D. for statistical assistance.
Publisher Copyright:
© 2022
PY - 2022
Y1 - 2022
N2 - The GlideScope® Spectrum™ single use blades, LoPro S1 and LoPro S2, offer several technical improvements over their predecessors while maintaining the traditional curvature useful in difficult airway scenarios. We performed a single-site, prospective randomized feasibility study with three different pediatric manikin models using these new blades. The primary outcome was first attempt success rate. Secondary outcomes were overall success rate, time to intubation, and Cormack and Lehane glottic view grade. A questionnaire was also administered to each participant following the intubation attempts to gauge their satisfaction with the Spectrum™ blades and proprietary stylet. Fifty total anesthesia providers consisting of attendings (consultants), residents, fellows, certified nurse anesthetists and certified anesthesiologist assistants intubated 3 different manikins, three times each, using both the LoPro S1 and LoPro S2 blades for a total of 18 intubations each. The overall success rate across all blades and manikins was 98% and greater. The median time to intubation for all blade and manikin combinations was less than 13 s. This study demonstrates the GlideScope® Spectrum™ LoPro S1 and LoPro S2 blades are effective video intubation devices, even in a difficult airway pediatric manikin model.
AB - The GlideScope® Spectrum™ single use blades, LoPro S1 and LoPro S2, offer several technical improvements over their predecessors while maintaining the traditional curvature useful in difficult airway scenarios. We performed a single-site, prospective randomized feasibility study with three different pediatric manikin models using these new blades. The primary outcome was first attempt success rate. Secondary outcomes were overall success rate, time to intubation, and Cormack and Lehane glottic view grade. A questionnaire was also administered to each participant following the intubation attempts to gauge their satisfaction with the Spectrum™ blades and proprietary stylet. Fifty total anesthesia providers consisting of attendings (consultants), residents, fellows, certified nurse anesthetists and certified anesthesiologist assistants intubated 3 different manikins, three times each, using both the LoPro S1 and LoPro S2 blades for a total of 18 intubations each. The overall success rate across all blades and manikins was 98% and greater. The median time to intubation for all blade and manikin combinations was less than 13 s. This study demonstrates the GlideScope® Spectrum™ LoPro S1 and LoPro S2 blades are effective video intubation devices, even in a difficult airway pediatric manikin model.
KW - GlideScope spectrum
KW - Manikin study
KW - Pediatric airway
UR - http://www.scopus.com/inward/record.url?scp=85123727224&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85123727224&partnerID=8YFLogxK
U2 - 10.1016/j.tacc.2022.01.002
DO - 10.1016/j.tacc.2022.01.002
M3 - Article
AN - SCOPUS:85123727224
SN - 2210-8440
JO - Trends in Anaesthesia and Critical Care
JF - Trends in Anaesthesia and Critical Care
ER -