T1 - Adverse Events Associated with Cardiac Catheterization in Children Supported with Ventricular Assist Devices
AU - Power, Alyssa
AU - Navaratnam, Manchula
AU - Murray, Jenna M.
AU - Peng, Lynn F.
AU - Rosenthal, David N.
AU - Dykes, John C.
AU - Yarlagadda, Vamsi V.
AU - Maeda, Katsuhide
AU - Almond, Christopher S.
AU - Chen, Sharon
N1 - Publisher Copyright:
© 2022 Lippincott Williams and Wilkins. All rights reserved.
PY - 2022/9/1
Y1 - 2022/9/1
N2 - Children on ventricular assist device (VAD) support can present several unique challenges, including small patient size, univentricular or biventricular congenital heart disease (1V- or 2V-CHD) and need for biventricular VAD (BiVAD) support. While cardiac catheterization can provide valuable information, it is an invasive procedure with inherent risks. We sought to evaluate the safety of catheterization in pediatric patients on VAD support. We performed a retrospective review of patients on VAD support who underwent catheterization at Lucile Packard Children's Hospital between January 1, 2014 and September 1, 2019. Using definitions adapted from Pedimacs, adverse events (AEs) after catheterization were identified, including arrhythmia; major bleeding or acute kidney injury within 24 hours; respiratory failure persisting at 24 hours; and stroke, pericardial effusion, device malfunction, bacteremia or death within 7 days. AEs were categorized as related or unrelated to catheterization. Sixty procedures were performed on 39 patients. Underlying diagnoses were dilated cardiomyopathy (48%), 1V-CHD (35%), 2V-CHD (8%), and other (8%). Devices were implantable continuous flow (72%), paracorporeal pulsatile (18%) and paracorporeal continuous flow (10%). Catheterizations were performed on patients in the ICU (60%), on inotropic support (42%), with deteriorating clinical status (37%) and on BiVAD support (12%). There were 9 AEs possibly related to catheterization including 6 episodes of respiratory failure, 2 major bleeding events, and 1 procedural arrhythmia. AE occurrence was associated with ICU status (P = 0.01), BiVAD support (P = 0.04) and procedural indication to evaluate worsening clinical status (P = 0.04). Despite high medical acuity, catheterization can be performed with an acceptable AE profile in children on VAD support.
AB - Children on ventricular assist device (VAD) support can present several unique challenges, including small patient size, univentricular or biventricular congenital heart disease (1V- or 2V-CHD) and need for biventricular VAD (BiVAD) support. While cardiac catheterization can provide valuable information, it is an invasive procedure with inherent risks. We sought to evaluate the safety of catheterization in pediatric patients on VAD support. We performed a retrospective review of patients on VAD support who underwent catheterization at Lucile Packard Children's Hospital between January 1, 2014 and September 1, 2019. Using definitions adapted from Pedimacs, adverse events (AEs) after catheterization were identified, including arrhythmia; major bleeding or acute kidney injury within 24 hours; respiratory failure persisting at 24 hours; and stroke, pericardial effusion, device malfunction, bacteremia or death within 7 days. AEs were categorized as related or unrelated to catheterization. Sixty procedures were performed on 39 patients. Underlying diagnoses were dilated cardiomyopathy (48%), 1V-CHD (35%), 2V-CHD (8%), and other (8%). Devices were implantable continuous flow (72%), paracorporeal pulsatile (18%) and paracorporeal continuous flow (10%). Catheterizations were performed on patients in the ICU (60%), on inotropic support (42%), with deteriorating clinical status (37%) and on BiVAD support (12%). There were 9 AEs possibly related to catheterization including 6 episodes of respiratory failure, 2 major bleeding events, and 1 procedural arrhythmia. AE occurrence was associated with ICU status (P = 0.01), BiVAD support (P = 0.04) and procedural indication to evaluate worsening clinical status (P = 0.04). Despite high medical acuity, catheterization can be performed with an acceptable AE profile in children on VAD support.
KW - cardiac catheterization
KW - complications
KW - mechanical circulatory support
KW - pediatrics
KW - ventricular assist device
UR - http://www.scopus.com/inward/record.url?scp=85137746055&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85137746055&partnerID=8YFLogxK
U2 - 10.1097/MAT.0000000000001627
DO - 10.1097/MAT.0000000000001627
M3 - Article
C2 - 34967779
AN - SCOPUS:85137746055
SN - 1058-2916
VL - 68
SP - 1174
EP - 1181
JO - ASAIO Journal
JF - ASAIO Journal
IS - 9
ER -