TY - JOUR
T1 - A general algorithm for distributed treatments of multiple brain metastases
AU - Chen, Mingli
AU - Wardak, Zabi
AU - Stojadinovic, Strahinja
AU - Gu, Xuejun
AU - Lu, Weiguo
N1 - Publisher Copyright:
© 2021 American Association of Physicists in Medicine
PY - 2021/4
Y1 - 2021/4
N2 - Purpose: Stereotactic radiosurgery (SRS) has become a primary treatment for multiple brain metastases (BM) but may require distribution of BMs over several sessions to make delivery time and radiation toxicity manageable. Contrasting to equal fraction dose in conventional fractionation, distributed SRS delivers full dose to a subset of BMs in each session while avoiding adjacent BMs in the same session to reduce toxicity from overlapping radiation. However, current clinical treatment planning for distributed SRS relies on manual BM assignment, which can be tedious and error prone. This work describes a novel approach to automate the distribution of BM in the Gamma Knife (GK) clinical workflow. Methods: We represent each BM as an electrostatic field of the same polarity that exerts repulsive forces on other BMs in the same session. This representation naturally leads to separation of close BMs into different sessions to lower the potential energy. Indeed, the BM distribution problem can be formulated as minimization of the total potential energy from all treatment sessions subject to delivery time constraints in mixed-integer quadratic programming (MIQP). We retrospectively studied eight clinical GK cases of multiple BM and compared the automated MIQP solution with clinically used BM distribution to demonstrate the efficacy of the proposed approach. Results: With the problem size equal to the number of BMs times the number of sessions, this MIQP can be solved in a minute on a personal workstation. The MIQP solution effectively separated BMs for a given number of treatment sessions and evened out the delivery time distribution among sessions. Compared to the clinically used manual BM distributions in paired t-test for a similar range of delivery time variation, the automated BM distributions had lower energy objectives (range of decrease: [11% 89%]; median: 25%; (Formula presented.)), more uniformly distributed treatment volumes (range of decrease for the normalized standard deviation of volume distribution: [0.02 0.95]; median: 0.16; (Formula presented.)), more scattered BMs in each treatment session (range of increase for the mean minimum BM distance: [0 14] mm; median: 6 mm; (Formula presented.)), and lower overall (Formula presented.) (range of decrease: [0.0 1.6] cc; median: 0.2 cc; (Formula presented.)). Moreover, without distribution, that is, with all BMs treated in the same session, (Formula presented.) was substantially larger compared to both manual and automated BM distributions; the increase ranged from 0.1 to 16.6 cc with a median of 1.3 cc. Conclusions: The proposed approach models the clinical practice and provides an efficient solution for optimal selection of BM subsets for distributed SRS. Further evaluations are underway to establish this approach as a tool for improving clinical workflow and to facilitate systematic study on the benefits of distributed SRS treatments.
AB - Purpose: Stereotactic radiosurgery (SRS) has become a primary treatment for multiple brain metastases (BM) but may require distribution of BMs over several sessions to make delivery time and radiation toxicity manageable. Contrasting to equal fraction dose in conventional fractionation, distributed SRS delivers full dose to a subset of BMs in each session while avoiding adjacent BMs in the same session to reduce toxicity from overlapping radiation. However, current clinical treatment planning for distributed SRS relies on manual BM assignment, which can be tedious and error prone. This work describes a novel approach to automate the distribution of BM in the Gamma Knife (GK) clinical workflow. Methods: We represent each BM as an electrostatic field of the same polarity that exerts repulsive forces on other BMs in the same session. This representation naturally leads to separation of close BMs into different sessions to lower the potential energy. Indeed, the BM distribution problem can be formulated as minimization of the total potential energy from all treatment sessions subject to delivery time constraints in mixed-integer quadratic programming (MIQP). We retrospectively studied eight clinical GK cases of multiple BM and compared the automated MIQP solution with clinically used BM distribution to demonstrate the efficacy of the proposed approach. Results: With the problem size equal to the number of BMs times the number of sessions, this MIQP can be solved in a minute on a personal workstation. The MIQP solution effectively separated BMs for a given number of treatment sessions and evened out the delivery time distribution among sessions. Compared to the clinically used manual BM distributions in paired t-test for a similar range of delivery time variation, the automated BM distributions had lower energy objectives (range of decrease: [11% 89%]; median: 25%; (Formula presented.)), more uniformly distributed treatment volumes (range of decrease for the normalized standard deviation of volume distribution: [0.02 0.95]; median: 0.16; (Formula presented.)), more scattered BMs in each treatment session (range of increase for the mean minimum BM distance: [0 14] mm; median: 6 mm; (Formula presented.)), and lower overall (Formula presented.) (range of decrease: [0.0 1.6] cc; median: 0.2 cc; (Formula presented.)). Moreover, without distribution, that is, with all BMs treated in the same session, (Formula presented.) was substantially larger compared to both manual and automated BM distributions; the increase ranged from 0.1 to 16.6 cc with a median of 1.3 cc. Conclusions: The proposed approach models the clinical practice and provides an efficient solution for optimal selection of BM subsets for distributed SRS. Further evaluations are underway to establish this approach as a tool for improving clinical workflow and to facilitate systematic study on the benefits of distributed SRS treatments.
KW - brain metastases (BM)
KW - distributed SRS
KW - stereotactic radiosurgery (SRS)
UR - http://www.scopus.com/inward/record.url?scp=85101274431&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85101274431&partnerID=8YFLogxK
U2 - 10.1002/mp.14722
DO - 10.1002/mp.14722
M3 - Article
C2 - 33449357
AN - SCOPUS:85101274431
SN - 0094-2405
VL - 48
SP - 1832
EP - 1838
JO - Medical physics
JF - Medical physics
IS - 4
ER -