A comparative evaluation of glycosylated haemoglobin assays: feasibility of references and standards

C. M. Peterson, L. Jovanovic, Philip Raskin, D. E. Goldstein

Research output: Contribution to journalArticlepeer-review

21 Scopus citations

Abstract

Four assays; high pressure liquid chromatography, colorimetric with thiobarbituric acid, affinity columns, and microcolumn cation exchange were compared for (1) ability to discriminate between samples taken from diabetic and normal subjects; (2) correlation with each other; (3) stability over time at different temperatures; and (4) reproducibility between laboratories. The most discriminatory (10 samples from a diabetic and 10 samples from a normal group) was the microcolumn cation exchange method (t=5.25; p<0.001), but all were significantly different at p<0.005. The intra-assay coefficient of variation was 1%-6%, except for the affinity column method which was 13% in normal subjects. High pressure liquid chromatography was used as a reference and the other assays correlated well (r=0.93-0.99). Storage at-80 °C, -20 °C, 4 °C, and 24 °C showed marked differences. The thiobarbituric acid method results were stable except for 24 °C. Microcolumn cation exchange was labile under all conditions. Affinity column was stable for up to 15 days, only if samples were stored as whole blood. High pressure liquid chromatography showed an increase in haemoglobin A1a+b and a decrease in the haemoglobin A1c. Haemoglobin A1c was reproducible for 4 days when stored at 4 °C and up to 11 days when stored at -80 °C. Samples exchanged between centres at 4 °C and performed within 5 days by high pressure liquid chromatography for haemoglobin A1 and haemoglobin A1c correlated well (r=0.98 and 0.99). Samples exchanged between centres after storage (up to 40 days -80°C) correlated (r=0.99) by the thiobarbituric acid method. Thus, standards can be prepared for the thiobarbituric acid method and this method with high pressure liquid chromatography could be used to establish references for clinical assays.

Original languageEnglish (US)
Pages (from-to)214-217
Number of pages4
JournalDiabetologia
Volume26
Issue number3
DOIs
StatePublished - Mar 1984

Keywords

  • Glycosylated haemoglobin
  • affinity column
  • high pressure liquid chromatography
  • microcolumn
  • references
  • standards
  • thiobarbituric acid

ASJC Scopus subject areas

  • Internal Medicine
  • Endocrinology, Diabetes and Metabolism

Fingerprint

Dive into the research topics of 'A comparative evaluation of glycosylated haemoglobin assays: feasibility of references and standards'. Together they form a unique fingerprint.

Cite this